4.1.1 Safety Measures • Laser emission indicator lamp The amplifier is equipped with an LED lamp which indicates when a laser beam is being emitted. The operator can see that this LED is on even when wearing protective g…

100%1 / 331
4.1 Adjustable Rail Engagement Sensor
The following laser type sensor is used on the CP-643E/643ME as the main conveyor’s
adjustable rail engagement sensor.
Item name: Laser type fiber sensor
Model: FS-L71
Wavelength: 670 mm
Max. output: 3 mW
Class: 2
The following labels must be affixed on machines using the laser type sensor.
On front cover:
At center adjustable rail engagement sensor, in-carrier open/close cylinder, and
out-carrier open/close cylinder:
LASER RADIATION--
DO NOT STARE INTO BEAM
670nm
3.0mW
300µW
2.5µSEC
SEMICONDUCTOR LASER
MAXIMUM OUTPUT
(AVERAGE OUTPUT)
PULSE DURATION
CLASS II LASER PRODUCT
CAUTION
AVOID EXPOSURE
LASER RADIATION
IS EMITTED FROM
THIS APERTURE.
CP6M10018
LASER RADIATION
DO NOT STARE INTO BEAM
CLASS2 LASER PRODUCT
Maximum output
Pulse duration
Emitted wavelength
3mW
2.5µs
670nm
in conformity to IEC825 -1 11.1993
CP6M10017
Part 9 Chapter 4 Main Conveyor
Edition 1.0 9-4-2 CP-6-series Mechanical Reference
4.1.1 Safety Measures
Laser emission indicator lamp
The amplifier is equipped with an LED lamp which indicates when a laser beam is
being emitted. The operator can see that this LED is on even when wearing
protective goggles.
Laser beam shield
A laser beam shield which can be attached to the fiber unit is supplied with FS-L
series sensors. Be sure to attach this shield when the operator must work in front of
the fiber unit where there is a risk of eye injury caused by the laser beam.
Stopping the laser emission
Laser beam emission is stopped when the fiber unit is disconnected from the
amplifier unit.
Fiber unit
Laser beam shield attached
CP6M10019
Part 9 Chapter 4 Main Conveyor
Edition 1.0 9-4-3 CP-6-series Mechanical Reference
4.1.2 Adjusting the Sensor Position
WARNING
Never look directly into the laser beam as this can damage the eyes.
1. Perform the following command sequence to move the main table to the loading
position: [LOADER] - [LOADING PSTN] - START button.
2. Press the EMERGENCY STOP button to cut off the 200V power. Only the 100V
power should remain on.
WARNING
Turn off the 200 V servo power before carrying out this work.
3. With the main conveyor’s adjustable rail engaged with the in- and out-conveyors’
adjustable rails, secure the sensor at the position where the seal’s silver area can be
detected.
Adjustable rail engagement
sensor 1
Adjustable rail engagement
sensor 2 Adjustable rail engagement
sensor 3
CP6M10020
(Toward the right)
(Center)
(Toward the left)
(Center)
IN loading
position
OUT loading
position
Part 9 Chapter 4 Main Conveyor