Caution: Do not disassemble the nozzle shaft assembly carelessly. Special equipment and
skills are required to perform the reassembly of the nozzle shaft. Such procedures
should be attempted only by users who have attended training at Fuji and are
equipped with the necessary tools, or whilst under the direct guidance of a
serviceman.
Bracket
Linear guide
Outer shaft
Clutch
Bolt
Caution : Washers may jump when the bolt
is loosened because of the spring
under the clutch.
Spring
Use a torque wrench to apply
20 kgf.cm to the screws (A and B)
when attaching the nozzle axis.
Refer to the table below.
Rotate the nozzle shaft
while holding the bolt
with your finger
A
B
X No. Part
Bolt
size
Bracket
No.
Torque
Kgf/cm
~ 166
167 ~
260
261
A
B
A
B
A
B
M4
M4
M4
M5
M4
M5
WPH0331
WPH0331
WPH0331
WPH1031
WPH0331
WPH1020
20
33
20
40
20
40
A
B
M4
M4
20
20
(4000 TYPE) (5000 TYPE)
Bracket
Vacuum hose
Part
Bolt
size
Torque
Kgf/cm
CP6M5044
Nozzle
shaft
assembly
Part 5 Chapter 3 Station Adjustments
Edition 1.0 5-3-26 CP-6-series Mechanical Reference
4. Move the area for the removed axis to station 11, then use I/O (Y028 PLACE SOL
ON) to operate the lever.
5. Set the cam angle within the range shown below, and position the dial gauge as
shown in the figure above.
CP6-4000 = 313° ~ 53°• CP6-5000 = 308° ~ 75°
6. Adjust the rod so that there is 0 ±0.03 difference between the slider groove and the
fixed groove in the cam.
7. Reattach the nozzle shaft assembly in the original location.
Using the clutch alignment jig, reverse the removal procedures to attach the
assembly.
CP6M5045
0±0.03 mm
Adjustment bolt
Rod
Slider
Fixed barrel
cam
Part 5 Chapter 3 Station Adjustments
Edition 1.0 5-3-27 CP-6-series Mechanical Reference
3.5.2 Adjusting the Nozzle UP Limit and DOWN Limit Sensors
The nozzle UP limit and DOWN limit sensors which detect the height of the nozzle
UP/DOWN rod are mounted inside the cam box. Adjust the mounting positions of
these sensors so that they switch ON when the nozzle is at its UP limit and DOWN limit
positions.
WARNING
Turn off the 200 V servo power before carrying out this work.
Exercise extreme caution when working on the machine if the cam is
not at its origin (0 deg.). Recoil of the cam axis can endanger the
operator.
Nozzle UP Limit Sensor
1. Set the cam axis at the 0-degree position.
2. Execute the following I/O commands to pull in the ST11 placing stop cylinder
(located in the cam box):
[SET] - [MANUAL] - [I/O] - [Standard I/O] - [OUTPUT] -> Y028 PLACE SOL ON
The cam lever will then follow the cam axis.
Solenoid valve
ST11 placing stop cylinder
Cam lever
Cam axis
CP6M5046
Part 5 Chapter 3 Station Adjustments
Edition 1.0 5-3-28 CP-6-series Mechanical Reference