Part 9 Chapter 3 In-Carrier Edition 1.4 9-3-3 CP-6-series Mechanical Reference Note: Perform the above adjustment on the four carrier open/close cylinders. CP6M10015

100%1 / 331
3.1 Adjustment of the In-Carrier Open/Close Limit Sensors
WARNING
Turn off the 200 V servo power before carrying out this work.
The CP-643E/643ME conveyor is equipped with laser sensors.
In areas where there is a risk of eye damage from the laser beams,
be sure to install a laser beam shield at the laser emission area
before performing this sensor adjustment procedure.
1. Release the air inside the cylinder.
2. Set the cylinder in the extended status and check the position at which the open
limit sensor comes ON.
3. From the position at which the sensor comes ON, move the open limit sensor back
by 0.5 mm and secure it in place.
Note: Perform this adjustment on the four carrier open/close cylinders.
4. Set the carrier to the closed status and check the position at which the closed limit
sensor comes ON.
5. From the position at which the sensor comes ON, move the closed limit sensor
forward 1.0 mm and secure it in place.
Closed limit sensor
Dog
a: Position at which the closed limit sensor comes
ON with the carrier in the closed status
CP6M10027a
a a
1.0 mm
a
Open limit sensor
a: Position at which the open limit sensor comes
ON with the cylinder in the extended status
0.5 mm
CP6M10013
Part 9 Chapter 3 In-Carrier
Edition 1.4 9-3-2 CP-6-series Mechanical Reference
Part 9 Chapter 3 In-Carrier
Edition 1.4 9-3-3 CP-6-series Mechanical Reference
Note: Perform the above adjustment on the four carrier open/close cylinders.