CP-6-series Mechanical Reference.pdf - 第319页

Link Bracket T able Next Stage Required BK T Remarks LGC-4020B C, P , I LGC-4020B C, I Reverse-flow Previous Stage Required BKT Remarks CAC-3100 G G , G CAC-5100 CAC-5060 CC, G CBC- ✻✻ ✻✻ BW , C LGC-4010B C, P , I Revers…

100%1 / 331
Pneumatic Spring
Place a level on the machine, and adjust the Y-direction levelness only. The air supply
timing is adjusted according to the length of the mechanical valve's bolt.
Caution: Be sure that the rear side of the machine is not too high.
1.5 Changing The Conveyor Link Bracket
Change to the brackets shown below.
List of Changed Parts
Dwg. No. Part Name Qty Type
93305WAB1000 BKT 2 Equivalent to previous Ctype
93305WAB1010 BKT 1 Equivalent to previous Gtype
CP6M1106
93305WAB1000
93305WAB1010
Part 10 Chapter 1 Vibration Reduction Unit
Edition 1.0 10-1-6 CP-6-series Mechanical Reference
Link Bracket Table
Next Stage Required BKT Remarks
LGC-4020B C, P, I
LGC-4020B C, I Reverse-flow
Previous Stage Required BKT Remarks
CAC-3100 GG, G
CAC-5100
CAC-5060 CC, G
CBC-✻✻ ✻✻BW,C
LGC-4010B C, P, I Reverse-flow
MCIDF-✻✻ ✻✻BV,C
Part 10 Chapter 1 Vibration Reduction Unit
Edition 1.0 10-1-7 CP-6-series Mechanical Reference
Notes:
Part 10 Chapter 1 Vibration Reduction Unit
Edition 1.0 10-1-8 CP-6-series Mechanical Reference