3.1 1 Station 19 Nozzle Dection Sensor Station 19 uses three nozzle detection sensors to detect which of the six nozzles was selected during nozzle selection at station 18. The adjustments are the same as for station 17.…

100%1 / 331
3.10.2 Adjustment of Interference Prevention Sensor
WARNING
Turn off the 200 V servo power before carrying out this work.
1. Ensure that the lever is lying horizontally, as shown in the figure above.
2. Gradually raise the position of the sensor bracket. The sensor LED should change
from ON to OFF at the appropriate position.
3. When the sensor LED changes to OFF as specified above, raise the sensor bracket a
further 0.5 mm.
Sensor OFF
0.5 mm UP
Sensor
Dog
Lever
Adjustment bolt
Horizontal
CP6M5070
Part 5 Chapter 3 Station Adjustments
Edition 1.0 5-3-45 CP-6-series Mechanical Reference
3.11 Station 19
Nozzle Dection Sensor
Station 19 uses three nozzle detection sensors to detect which of the six nozzles was
selected during nozzle selection at station 18.
The adjustments are the same as for station 17.
Part 5 Chapter 3 Station Adjustments
Edition 1.0 5-3-46 CP-6-series Mechanical Reference
4. XY-Table Movable Rail Engagement Check
Sensor
When the XY-table is to be raised, it is necessary for the movable rails on the in-conveyor,
XY-table, and out-conveyor to all be positioned in a line.
This sensor checks whether the positions of the movable rails on the XY-table and the
conveyors are aligned so that they can be engaged without causing interference with one
another.
4.1 Sensor Position Adjustment
1. Move the XY-table to the loading position using the command operation.
[LOADER] - [LOAD PSTN] - START button
2. Press the EMERGENCY STOP button. This will cut the 200V power and leave the
machine with only the 100V power on.
WARNING
Turn off the 200 V servo power before carrying out this work.
3. Secure the sensors in place where the silver portion of the rails can be checked and
the movable rail of the XY-table can be engaged with the rails on the in- and out-
conveyors. (2 locations; on the in-conveyor side and the out-conveyor side)
In-conveyor
XY-table
Out-conveyor
Engage check
sensor
XY-table movable rail
CP6M5071
Silver portion
Part 5 Chapter 4 Engagement Rail Adjustments
Edition 1.0 5-4-1 CP-6-series Mechanical Reference