X7056_Operating manual_en.pdf - 第173页

Maintenanc e Maintenance schedule 173 Inspection system X7056 | Operating manual | Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a 2-monthly maintenance Component Measures Time required Positionin g unit, flat panel detec…

100%1 / 280
Maintenance
Maintenance schedule
172
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
Monthly maintenance
Component Measures Time
required
System Make a safety backup of the
entire data base.
approx. 60
min.
System interior Perform these steps:
Check camera and motor
connections for damage.
Check cameras and motors
for mechanical damage.
approx. 10
min.
Positioning unit, linear
measuring scales
Perform these steps:
Inspect the positioning unit
and the linear measuring
scales for damage and
contamination.
Clean the positioning unit and
the linear measuring scales in
a horizontal direction with a
clean, soft, lint-free cloth.
Check of the measurement
system; optimize if required.
approx. 15
min.
Transport system, belts Perform these steps:
Inspect the transport system
and belts for damage and
contamination.
Check the calibration cross on
the transport plates for
damage and contamination.
Clean the transport system
and belts with a clean, soft
lint-free cloth to remove all
dust; remove any PCB
component debris.
Check transport and belts for
smooth movement.
approx. 15
min.
Shutter Visual check; functions check Approx.
5min.
Lift gate Visual check; functions check Approx.
5min.
Stopper Visual check; functions check Approx.
5min.
Safety circuits Check the safety features, see
„Installation“ > „Checking the
safety features“ (Page 92).
Approx.
5min.
Maintenance
Maintenance schedule
173
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
2-monthly maintenance
Component Measures Time
required
Positioning unit, flat
panel detector (FPD)
Perform these steps:
Check spindles for contami-
nation.
„Lubricating the runner
blocks and spindles“ (Page
192)Lubricate spindles, see
approx. 30
min.
3-monthly maintenance
Component Measures Time
required
System Perform a grayscale value cali-
bration.
approx. 30
min.
Positioning unit Perform these steps:
Check runner block for
contamination.
The guide carriage should
move easily, without deflec-
tion.
Grease runner blocks, see
„Lubricating the runner
blocks - AOI“ (Page 177).
Visual inspection of the
measurement tapes; clean if
necessary.
approx. 30
min.
Positioning unit Perform these steps:
Check runner block for
contamination.
The guide carriage should
move easily, without deflec-
tion.
Grease runner blocks, see
„Lubricating the runner
blocks - AXI“ (Page 181).
Visual inspection of the
measurement tapes; clean if
necessary.
approx. 30
min.
Transport system Perform these steps:
Make sure the screws are
tight.
Check transport system and
clamping for contamination.
Inspect the clamping; adjust
if necessary.
Visual check: transfer posi-
tion of the PCB.
approx. 10
min.
Z-Axis See „Lubricating the Z-axis“
(Page 196)
approx. 30
min.
Maintenance
Maintenance schedule
174
Inspection system X7056 | Operating manual |
Version 3.1 Rev.006| 2016-01-06 | 30.009.1930a
Lift gate See „Lubricating the lift gate“
(Page 198)
approx. 30
min.
Positioning unit, flat
panel detector (FPD)
Perform these steps:
Check runner block for
contamination.
The guide carriage should
move easily, without deflec-
tion.
Grease runner blocks, see
„Lubricating the runner
blocks and spindles“ (Page
192).
approx. 30
min.
Positioning unit, flat
panel detector (FPD)
Perform these steps:
Check belts for damage and
contamination.
Clean the transport system
and belts with a clean, soft
lint-free cloth to remove all
dust.
Check belts for smooth
movement.
approx. 15
min.
X-ray tube When tube is longer not used,
perform a warmup, see „Warm-
up procedure“ (Page 220)
Depending
on how long
the tube is
switched off
AOI system computer Perform these steps:
Check the ventilator function.
Visual check of filter mats on
system computer.
If mats are contaminated,
remove them and blow out
with compressed air.
If any defects, exchange filter
mat, see „Exchanging filter
mat on AOI system
computer“ (Page 223).
approx. 5-
15 min.
System computer AXI Perform these steps:
Check the ventilator function.
Visual check of filter mats on
system computer and
housing.
If mats are contaminated,
remove them and blow out
with compressed air.
If any defects, exchange filter
mat, see „Exchanging filter
mat on AXI system
computer“ (Page 225).
approx. 5-
15 min.
XM sensor head, XM 3-D
camera technology
Check the ventilator function. approx. 5-
15 min.
3-monthly maintenance (Forts.)
Component Measures Time
required