1OM-1075-002.pdf - 第101页
AHB01EOPP 1.1.2 Confirmation of Safety Doors and Feeder Base Pullout Prevention Bars (1) Confirm that the front and rear safety doors are closed. (2) Confirm that all feeder base pullout prevention bars are closed. Fig. …

AHB01EOPP
Fig. 1C3-1
Do not change the set air pressure. Otherwise, the
pneumatic devices will not work normally.
(a) The pressure switch is correctly set. Be sure not to adjust it.
(Reference) 0.35 MPa (3.6 kgf/cm
2
)
(b) Never adjust the air blowing pressure. The pressure is al-
ready set to "0.05 MPa (0.5 kgf/cm
2
).
(c) Dry and Clean Air
Be sure to use dry and clean air. If moisture, oil, dust, etc.,
enter a pneumatic device (air cylinder, etc., used in this
machine), it will result in a breakdown of the machine.
Dry and Clean Air:
Moisture : Dew Point -17°C or lower (Atmospheric Pres-
sure)
Oil : 0.1 mg/m
3
or less (ANR)
Dust : Solid Material 0.01 µm or less
1.1 Inspections before Automatic Operation
0308-004 3-3
Note
CAUTION

AHB01EOPP
1.1.2 Confirmation of Safety Doors and Feeder Base Pullout
Prevention Bars
(1) Confirm that the front and rear safety doors are closed.
(2) Confirm that all feeder base pullout prevention bars are closed.
Fig. 1C4 Safety Doors
1.1 Inspections before Automatic Operation
0206-003 3 - 4

AHB01EOPP
1.2 Preparation before Operation
1.2.1 Power ON Operation
(1) Reconfirm that the safety doors and the feeder base pullout preven-
tion bars are closed.
(2) Remove the padlock from the lock lever of the power breaker.
Fig. 1C5
0308-004 3-5