0308-004 2 0 AHB01EOPP 2.5 Pre-Installation Checks • Do not expose the machine to combustible or corrosive gas. • Select a place free of lamp soot and dust. Fig. 1X21 • Level the machine at the correct height, using a le…

100%1 / 145
Fig. 1X19
Ambient temperature must be 20±10°C and humidity 30% to 80%. Any dew
condensation must be avoided.
When the machine is transferred to another place and the ambient temperature
rises more than the surface of the machine, dew may condense under the
condition described below.
Note that dew condensation may cause the machine to break down.
Condition of Dew Condensation
Dew may condense when the difference (based on "Humidity (%)") between the
ambient temperature of the destination (the place where the machine was
transferred) and the surface temperature of the machine reach the values or
more in the table below.
Ensure that the selected place is free of electric noise, etc.
Precautionary measures (prevention of noise generation, etc.,) must be taken for
other equipment to prevent malfunctions.
0308-004 1 9 AHB01EOPP
Humidity (%) of Destination
Differences between Ambient Temperature of
Destination and Surface Temperature of Machine
80 3°C or more
70 6°C or more
60 8°C or more
50 10°C or more
40 14°C or more
30 18°C or more
Fig. 1X20
2.5 Pre-Installation Checks
0308-004 2 0 AHB01EOPP
2.5 Pre-Installation Checks
Do not expose the machine to combustible or corrosive gas.
Select a place free of lamp soot and dust.
Fig. 1X21
Level the machine at the correct height, using a level vial.
Fig. 1X22
The machine should be free of obstacles around it for easy maintenance.
Fig. 1X23
Fig. 1X24
Connect the primary power supply to Terminals "L1", "L2", and "L3" and the ground-
ing wire to the bolt at the grounding mark located on the right side of the power
breaker.
Voltage : 200±20 V AC, 3-Phase
Apparent Power : Approx. 5 kVA for TIM-X100
Note: Make the PE wire longer than the others (L1, L2, and L3), giving some
leeway.
Grounding
L1
(R)
L2
(S)
L3
(T)
Fig. 1X25
Fig. 1X26
Clean, dry, and non-lubricated air (air containing no moisture, oil, and dust) must
be supplied at an air pressure of 0.49 to 0.69 MPa (5 to 7 kgf/cm
2
).
0308-005 2 1 AHB01EOPP
2.5 Pre-Installation Checks