1OM-1075-002.pdf - 第59页
*5 [PNL CHANGE] Button • This button is used to select either the front or the rear operation panel. (a) The other operation panel can be selected by press- ing the [PNL CHANGE] button on the unavailable (in- valid) side…

*1 [POWER ON] Button
• This button is used to turn on the power for operations.
*2 [START] Button
• This button is used to start the automatic operation.
The automatic operation can be started only when the lamp is
flickering.
• While the LED of this button is ON, it indicates that the machine is
running automatically.
When the [STOP] button is pressed during automatic operation,
the LED extinguishes.
The lamp is kept ON while each device is being zeroed.
*3 [STOP] Button
• This button is used to stop the automatic operation.
• When this button is pressed during zeroing operation, the zeroing
operation of each device is interrupted, excluding the P.C.B. trans-
fer.
*4 [ENABLE] Button
• When the [ON] button (entitled "MOVE") is pressed in the active
touch screen, the LED of the [ENABLE] button illuminates for two
seconds.
When the [ENABLE] button is pressed with its LED "ON", the ma-
chine performs various operations selected in the operation win-
dows.
0206-003 1-13
AHB01EOPP
2.3 Equipment for Operations
Note

*5 [PNL CHANGE] Button
• This button is used to select either the front or the rear operation
panel.
(a) The other operation panel can be selected by press-
ing the [PNL CHANGE] button on the unavailable (in-
valid) side only when the currently selected panel is
not set in the "Operation Locked" mode.
(b) While the LED of this button is ON, the followings be-
come available.
Front Touch Screen
[START] Button
[STOP] Button
[ENABLE] Button
[READY] Button
[OPERATION] Switch
[EMERGENCY STOP] Switch
Pointing Device
Keyboard
(c) The [STOP] button and [EMERGENCY STOP] switch
are always available regardless of the [PNL CHANGE]
button.
(d) When the panel operation is not locked and the [STOP]
button on the unselected operation panel is pressed,
the operation panel on the pressed button side be-
comes activated automatically.
• When this button is pressed with the LED "ON", the "LOCK" lamp
illuminates, indicating that only the front panel is available (Opera-
tion Locked).
To cancel the "LOCK" mode, press this button again.
*6 [LOCK] Lamp
• While the lamp is "ON", it indicates that only the front operation
panel is available and no panel change operation is possible.
• The lamp flickers when any operation is made on the rear
operation panel with the lamp being kept ON.
To cancel the flickering of the lamp, press the [PNL CHANGE]
button and follow the steps to set the operation-lock mode again.
*7 [READY] Button
• This button is used to turn on or off the electromagnetic lock of the
front safety door.
ON : The electromagnetic lock of the front safety door is
turned ON.
OFF : The electromagnetic lock of the front safety door is
turned OFF.
0308-004 1-14
AHB01EOPP
2.3 Equipment for Operations
Note

*8 [OPERATION] Switch
• The selection key must be inserted to change over the [OPERA-
TION] switch to "RUN" or "SETUP"
The [OPERATION] switch must be set to the "RUN" side for auto-
matic operation.
The switch can be changed over to "RUN" or "SETUP"
only when the machine is in the "STOP" mode.
• When the switch is changed to the "SETUP" side, the machine is
set as follows.
(a) The red, yellow, and green lamps of the light tower will illumi-
nate (initial setting of the machine upon shipment).
(b) The following operations are prohibited regardless of the front
safety door condition (opened/closed).
Automatic Operation, Zeroing Operation, Device Test, Unit
Adjustment, and Teaching Operation
(c) Operations automatically become available on the front op-
eration panel (operations locked).
No operations are accepted on the rear operation panel.
• When the [OPERATION] switch is set to the
"SETUP" side, the interlock system of the front
safety door is deactivated.
• Do not operate the machine with the [OPERATION]
switch in the "SETUP" mode except for the setup
operations.
• Do not keep the selection key inserted unless nec-
essary. The key shall be stored by the person in
charge.
• When the selection key is turned forcibly, the switch
may be damaged.
*9 [EMERGENCY STOP] Switch
• This switch is used to stop the machine immediately in an emer-
gency.
• When this switch is pressed, the power is turned off and the ma-
chine stops immediately.
When the power is turned off, the LED of the [POWER ON] but-
ton on the operation panel illuminates in red.
0308-004 1-15
AHB01EOPP
2.3 Equipment for Operations
CAUTION
Note