*5 [PNL CHANGE] Button • This button is used to select either the front or the rear operation panel. (a) The other operation panel can be selected by press- ing the [PNL CHANGE] button on the unavailable (in- valid) side…

100%1 / 145
*1 [POWER ON] Button
This button is used to turn on the power for operations.
*2 [START] Button
This button is used to start the automatic operation.
The automatic operation can be started only when the lamp is
flickering.
While the LED of this button is ON, it indicates that the machine is
running automatically.
When the [STOP] button is pressed during automatic operation,
the LED extinguishes.
The lamp is kept ON while each device is being zeroed.
*3 [STOP] Button
This button is used to stop the automatic operation.
When this button is pressed during zeroing operation, the zeroing
operation of each device is interrupted, excluding the P.C.B. trans-
fer.
*4 [ENABLE] Button
When the [ON] button (entitled "MOVE") is pressed in the active
touch screen, the LED of the [ENABLE] button illuminates for two
seconds.
When the [ENABLE] button is pressed with its LED "ON", the ma-
chine performs various operations selected in the operation win-
dows.
0206-003 1-13
AHB01EOPP
2.3 Equipment for Operations
Note
*5 [PNL CHANGE] Button
This button is used to select either the front or the rear operation
panel.
(a) The other operation panel can be selected by press-
ing the [PNL CHANGE] button on the unavailable (in-
valid) side only when the currently selected panel is
not set in the "Operation Locked" mode.
(b) While the LED of this button is ON, the followings be-
come available.
Front Touch Screen
[START] Button
[STOP] Button
[ENABLE] Button
[READY] Button
[OPERATION] Switch
[EMERGENCY STOP] Switch
Pointing Device
Keyboard
(c) The [STOP] button and [EMERGENCY STOP] switch
are always available regardless of the [PNL CHANGE]
button.
(d) When the panel operation is not locked and the [STOP]
button on the unselected operation panel is pressed,
the operation panel on the pressed button side be-
comes activated automatically.
When this button is pressed with the LED "ON", the "LOCK" lamp
illuminates, indicating that only the front panel is available (Opera-
tion Locked).
To cancel the "LOCK" mode, press this button again.
*6 [LOCK] Lamp
While the lamp is "ON", it indicates that only the front operation
panel is available and no panel change operation is possible.
The lamp flickers when any operation is made on the rear
operation panel with the lamp being kept ON.
To cancel the flickering of the lamp, press the [PNL CHANGE]
button and follow the steps to set the operation-lock mode again.
*7 [READY] Button
This button is used to turn on or off the electromagnetic lock of the
front safety door.
ON : The electromagnetic lock of the front safety door is
turned ON.
OFF : The electromagnetic lock of the front safety door is
turned OFF.
0308-004 1-14
AHB01EOPP
2.3 Equipment for Operations
Note
*8 [OPERATION] Switch
The selection key must be inserted to change over the [OPERA-
TION] switch to "RUN" or "SETUP"
The [OPERATION] switch must be set to the "RUN" side for auto-
matic operation.
The switch can be changed over to "RUN" or "SETUP"
only when the machine is in the "STOP" mode.
When the switch is changed to the "SETUP" side, the machine is
set as follows.
(a) The red, yellow, and green lamps of the light tower will illumi-
nate (initial setting of the machine upon shipment).
(b) The following operations are prohibited regardless of the front
safety door condition (opened/closed).
Automatic Operation, Zeroing Operation, Device Test, Unit
Adjustment, and Teaching Operation
(c) Operations automatically become available on the front op-
eration panel (operations locked).
No operations are accepted on the rear operation panel.
When the [OPERATION] switch is set to the
"SETUP" side, the interlock system of the front
safety door is deactivated.
Do not operate the machine with the [OPERATION]
switch in the "SETUP" mode except for the setup
operations.
Do not keep the selection key inserted unless nec-
essary. The key shall be stored by the person in
charge.
When the selection key is turned forcibly, the switch
may be damaged.
*9 [EMERGENCY STOP] Switch
This switch is used to stop the machine immediately in an emer-
gency.
When this switch is pressed, the power is turned off and the ma-
chine stops immediately.
When the power is turned off, the LED of the [POWER ON] but-
ton on the operation panel illuminates in red.
0308-004 1-15
AHB01EOPP
2.3 Equipment for Operations
CAUTION
Note