1OM-1075-002.pdf - 第41页
0206-001 4 0 AHB01EOPP

4.2.6 Nozzle U/D Axis Pass Line Detection Sensors
These sensors are provided to protect the placement heads when the
nozzle U/D axis has dropped during movement of the X/Y beam.
Fig. 1X43
Sensor Name Symbol Countermeasures
Pass Line Detection
4.2.7 L-Axis Limit Detection Sensors
Sensor Name Symbol Countermeasures
(+) Limit Detection
(-) Limit Detection
4.2 Module Protection Sensors
0206-001 3 9 AHB01EOPP
Table 1X15
When this sensor is turned OFF (light emitted and not
received) while the X/Y beam is moving, the following
measures are taken.
• The excitations of the beam X/Y axis and the nozzle
U/D axis are shut off.
(At the same time, the nozzle U/D axis is braked.)
BPH023
Table 1X16
When one of the left sensors is turned off (E/NR) while
the X/Y beam is moving, the following measures are
taken. (E/NR: Light Emitted and Not Received)
• The excitation of the nozzle U/D axis is shut off.
(At the same time, the nozzle U/D axis is braked.)
BPH022
BPH021

0206-001 4 0 AHB01EOPP

Section 1
Scope
0308-002 1-A AHB01EOPP
This section explains the name and function of each sec-
tion and the mechanism of the surface mounting about the
multi-functional mounter.