SYS-CP842-1.1E.pdf - 第115页
3.Machine System SYS-CP842-1.1E 106 CP-842E / CP-842ME System Reference Editing Operations The following editing operations can be perfor med at this screen. Problem Editing Operation A vision processing error occurs dur…

SYS-CP842-1.1E 3.Machine System
CP-842E / CP-842ME System Reference 105
0: Backlight
1: Frontlight
E. [Body]: Switches to the body data editing screen.
F. [Element]: Switches to the element data editing screen.
G. [Lead]: Switches to the lead data editing screen.
H. [Close]: Returns to the production program editing screen.

3.Machine System SYS-CP842-1.1E
106 CP-842E / CP-842ME System Reference
Editing Operations
The following editing operations can be performed at this screen.
Problem Editing Operation
A vision processing error occurs during test
placement.
Error code: 0x1CA18005
No part line was found.
Error code: 0x1CA18006
No part line was found.
If the vision type is incorrect, edit the vision
type setting.
A vision processing error occurs during test
placement.
If the lighting is incorrect, edit the lighting
setting.
A vision processing error occurs during test
placement.
Error code: 0x1CB01101
Incorrect camera type setting.
If the camera type is incorrect, edit the
camera type setting.
T007E

SYS-CP842-1.1E 3.Machine System
CP-842E / CP-842ME System Reference 107
Element Data Editing Screen
Element data can be edited from this screen. For element data details, refer to the SMD3
Operation Manual.
Push the START button.
FUJI
Error
Operator
JOG:X Y CAM
Servo Count
GEMCCD Monitor
Element Data Editor
FUJI_CP7_2001
Front
Close
-0.6200
Position
X
Y
0.0000
[mm]
[mm]
0.1000
Lead Tolerance Values
Length
Width
0.1000
[mm]
[mm]
0.1000
Deviation
[mm]
Lead Data
Side
Number
0
P Pattern
3
Result 1
Pitch
0.0000
Width
0.3000
[mm]
0.5000
Length
[mm]
Count
1
[mm]
Lead
Body
Vision
Type
123
Sequence Number
1
Element
Set Switch
CP7S2020E
A
D
E
F
G
H
I
J
SRQP
B C
K
L
M
N
O