3.Machine System SYS-CP842-1.1E 116 CP-842E / CP-842ME System Reference 3.4 Maintenance Mode Maintenance mode override s the safety devices on the machine to allow for machine adjustment s. A maintenance key is necessary…

100%1 / 233
SYS-CP842-1.1E 3.Machine System
CP-842E / CP-842ME System Reference 115
3.3.4 Using the Data Manager
The data manager is a group of functions which assist users to administer the various kinds
of data held at the machine. Press [Maintenance] - [Data Manager] to display the [Data
Manager] screen.
Using these functions, users can copy data to the hard disk or floppy disk, or restore data
which has been lost or damaged.
3.Machine System SYS-CP842-1.1E
116 CP-842E / CP-842ME System Reference
3.4 Maintenance Mode
Maintenance mode overrides the safety devices on the machine to allow for machine
adjustments. A maintenance key is necessary to use maintenance mode.
3.4.1 Maintenance Mode Operation
The following operations are possible with the safety doors open when using Maintenance
Mode.
• Calibration data measurements (limited use)
• Position (limited use)
• I/O check
• Inching
3.4.2 Entering Maintenance Mode
Procedure
1. Open the front safety doors and turn the Maintenance key to the ON position.
2. In the [Main] screen, select [Maintenance] then [Maintenance Mode]. The [Maintenance
Mode] screen displays.
DANGER
Maintenance mode overrides the safety devices on the machine. Take extreme
care when operating the machine with the safety doors open.
C76M1030
Maintenance switch
Maintenance key
DANGER
Maintenance Mode and the Maintenance key should only be used by
experienced maintenance personnel.
SYS-CP842-1.1E 3.Machine System
CP-842E / CP-842ME System Reference 117
Note: During Maintenance Mode, “Maintenance Mode” displays and flashes in the production program name
area.
3. Select the necessary maintenance operation command from [Edit Configuration], [Edit
Calibration Data], [Calibration Data Measurement], [Loader Cylinder] and [I/O Check]
and perform the adjustment or maintenance.
4. When finished, press the [Close] button and the [Maintenance] screen returns.