SYS-CP842-1.1E.pdf - 第84页

SYS-CP842-1.1E 3.Machine System CP-842E / CP-842ME System Reference 75 3.2 Editing Production Programs On the Machine 3.2.1 Function Explanation This function uses the machine’ s vision processing function to check for d…

100%1 / 233
3.Machine System SYS-CP842-1.1E
74 CP-842E / CP-842ME System Reference
Display when [ 16 Division ] is selected
CP7S2026E
H10 N2
H10 N2
H14 N2
H14 N2
H2 N2
H2 N2
H6 N2
H6 N2
H11 N2
H11 N2
H15 N2
H15 N2
H3 N2
H3 N2
H7 N2
H7 N2
H12 N2
H12 N2
H0 N2
H0 N2
H4 N2
H4 N2
>>
>>
H8 N2
H8 N2
H13 N2
H13 N2
H1 N2
H1 N2
H5 N2
H5 N2
H9 N2
H9 N2
H10 N2
H14 N2
H2 N2
H6 N2
H11 N2
H15 N2
H3 N2
H7 N2
H12 N2
H0 N2
H4 N2
>>
H8 N2
H13 N2
H1 N2
H5 N2
H9 N2
SYS-CP842-1.1E 3.Machine System
CP-842E / CP-842ME System Reference 75
3.2 Editing Production Programs On the Machine
3.2.1 Function Explanation
This function uses the machine’s vision processing function to check for deviations between
the panel pattern or mounted parts, and the data image (wire frame). It also allows mark
data, placement coordinates, and part data to be fine-adjusted on the machine. This
function uses “simulation” and “test placement” commands. The wire frame, and the
“simulation” and “test placement” commands are explained below.
Wire Frame
The wire frame tool provides a visual representation of the mark and part data which is
registered in a production program.
Simulation Command
Acquires an image of the part placement position without the part being placed, and
displays a wire frame representation on the monitor.
1. Fiducial mark sequence
a. The panel’s mark pattern is compared with the wire frame to check for mark pattern
errors.
b. The panel’s mark pattern is compared with the wire frame to check for reading
position deviations.
2. Block skip mark sequence
a. The panel’s mark pattern is compared with the wire frame to check for reading
position deviations.
3. Placement sequence
a. The panel pattern is compared with the wire frame to check for part placement errors.
b. The panel pattern is compared with the wire frame to check for placement position
deviations.
c. The panel pattern is compared with the wire frame to check the part placement angle.
Note: When a placement position image is acquired at a placement sequence, the placement position is
corrected based on the vision processing result from the fiducial mark reading operation.
Fiducial marks: Draws the mark shapes and displays them on the monitor.
Block skip marks: Draws the mark images based on their X,Y sizes, and displays
them on the monitor.
Placement sequence: Draws the part shape and displays it on the monitor.
3.Machine System SYS-CP842-1.1E
76 CP-842E / CP-842ME System Reference
Test Placement Command
Places a part and acquires an image of the placement position, and displays a wire frame
representation on the monitor.
4. Placing sequence
The part is compared with the wire frame to check for feeder setup errors.
The part is compared with the wire frame to check the part supply direction.
3.2.2 Editing Production Programs
The “simulation” and “test placement” commands can be used to locate and edit production
program data errors and coordinate value deviations.
Procedure
The editing procedure steps are explained below.
1. Program check using the simulation command
a. Begin simulation in either the CONTINUOUS or STEP mode.
b. Check the panel pattern and wire frame match.
2. Editing and rechecking the program
a. Proceed to the data editing screen for the sequence to be edited, then edit the data
on the machine.
b. Begin another simulation of the edited sequence. Repeated simulations can be
performed for a sequence which is being edited.
Note: The panel is not unloaded when the simulation is completed.
3. Saving the edited program
a. Click the [Close] button at the simulation command screen to display a “save
production program” dialog box. When saved, production program overwriting
occurs.
4. Program check using the test placement command
a. Begin a test placement in either the CONTINUOUS or STEP mode.
b. Check the placed part and wire frame match.
5. Editing the program
a. Proceed to the data editing screen for the sequence to be edited, then edit the data
on the machine.
b. Execute the test placement command again.
Note:
1.
Another placement cannot be executed using edited data as this will result in a double
placement.
2.The panel is not unloaded when the test placement is completed.