SYS-CP842-1.1E.pdf - 第98页

SYS-CP842-1.1E 3.Machine System CP-842E / CP-842ME System Reference 89 Production Progra m Editing Screen Production programs can be edited from this screen. Screen Button Explanations Press the START button. FUJI Error …

100%1 / 233
3.Machine System SYS-CP842-1.1E
88 CP-842E / CP-842ME System Reference
Specifying A Sequence
The vicinity of the specified sequence part can be displayed by using the cursor movement
buttons, by touching the screen directly, by using the horizontal scrollbar, or by using the
zoom buttons. After displaying the part vicinity, the specified sequence part can be
displayed by using cursor movement buttons or by touching the screen directly. The
specified part displays in red.
O. [Close]: Returns to either the simulation or the test
placement screen (returns to the screen from which
this screen was accessed).
SYS-CP842-1.1E 3.Machine System
CP-842E / CP-842ME System Reference 89
Production Program Editing Screen
Production programs can be edited from this screen.
Screen Button Explanations
Press the START button.
FUJI
Error
Operator
JOG:X Y CAM
Servo CountGEMCCD Monitor
Production Program EditorFUJI_CP7_2001
Front
Close
1
Sequence Number
Pickup
Sequence
Body
Lead
Element
Vision
BS Mark
F Mark
Mark
Set
Set Switch
CP7S2012E
A
C
D
F
B
E
H
G
I
J
A. [Sequence No.]: Switches to the sequence search screen.
B. [Sequence]: Switches to the sequence data editing screen.
C. [Fiducial]: Switches to the F-mark data editing screen.
D. [Block Skip]: Switches to the BS-mark data editing screen.
E. [Body]: Switches to the body data editing screen.
F. [Lead]: Switches to the lead data editing screen.
G. [Element]: Switches to the element data editing screen.
H. [Vision Type]: Switches to the vision type editing screen.
I. [Pickup]: Switches to the pickup data editing screen.
J. [Close]: Returns to either the simulation or the test placement screen
(returns to the screen from which this screen was accessed).
3.Machine System SYS-CP842-1.1E
90 CP-842E / CP-842ME System Reference
Sequence Editing Screen
Sequence data can be edited from this screen.
Press the START button.
FUJI
ErrorOperator
JOG:X Y CAM
Servo CountGEM
CCD Monitor
Sequence Data EditorFUJI_CP7_2001
Front
Close
123
Pickup Location
Stage number
Group number
Slot number
Sub-slot number
X-coordinate
Y-coordinate
Q-rotation
-93.5000
52.0000
90.0000
[mm]
[mm]
[deg]
Direction
0
Sequence Type
D
Comment
MINI1220122
Sequence Number
1 0 13 0
-- -
Set Switch
Setup
1
2
CP7S2013E
A
B
C
D
E
GF