SYS-CP842-1.1E 3.Machine System CP-842E / CP-842ME System Reference 57 3.1.7 Setting the Pr oduction Quantity The machine can be set to produce up to 65 535 panels in auto matic operation. Th is setting can be made when …

100%1 / 233
3.Machine System SYS-CP842-1.1E
56 CP-842E / CP-842ME System Reference
Note: Pick up offset values set in part data and Auto pick up offset Y values cannot be changed manually.
5. Whenever the auto pick up offset function for X or Y needs to be enabled or disabled,
press the [Change] button next to the [Auto pick up offset X] or [Auto pick up offset Y]
buttons. Select [OK] on the confirmation window that displays.
Note: When the [Auto pick up offset X] function is enabled, placing positions are reevaluated and the
necessary auto pick up offsets are performed, even when pick up offset values have been set in part
data.
SYS-CP842-1.1E 3.Machine System
CP-842E / CP-842ME System Reference 57
3.1.7 Setting the Production Quantity
The machine can be set to produce up to 65535 panels in automatic operation. This setting
can be made when the production program is transmitted from the host (refer to your host
system documentation), or using commands at the machine.
Procedure
1. Press [Program] at the [Main] screen, and then press [Chg Scheduled Panels].
The numeric keypad displays.
2. Enter a value at the numeric keypad and press [OK].
The specified production quantity displays at the [Program] screen in the Scheduled
Panels column and also at the Scheduled Panels item at the [Production] screen when
viewed in the default [Loader] display mode.
3.1.8 Stopping and Restarting the Machine
Stopping the machine in an emergency.
• Push any of the EMERGENCY STOP buttons on the machine.
When the EMERGENCY STOP button is pushed the 200V power supply to the
servo system is cut, and the machine stops immediately. When pushed, the
button locks in position and must be turned in the direction of the arrows in order
to release it.
• When resuming operation, release the EMERGENCY STOP button, and then
press READY ON. Press the flashing START button to commence.
Stopping the machine at the end of the current cycle.
• Press the CYCLE STOP button.The machine stops at the end of the current
cycle. Pressing CYCLE STOP does not cut the 200V power.
• Press the flashing START button to resume operation.
Stopping the machine after completing the current panel(s).
• Press [Finish Current Panels] at the [Production] screen.The panel(s) currently
being produced is completed and sent to the next machine, then the machine
stops and the START button is enabled.
• Push the START button to resume operation.
3.Machine System SYS-CP842-1.1E
58 CP-842E / CP-842ME System Reference
3.1.9 Display During Production
Pressing [Production] at the [Main] screen enables the START button.
The following screen displays when production is started.
The operator can access four different production displays during operation. These
displays are changed using the buttons under Display at the bottom of the screen.
[Loader Data] The default screen is the loader data (shown above).
[Nozzle Data] The status of all the nozzles on the machine, including those
currently held by the placing head is shown at this screen.
[Production Info] Select to display production data for the current program.