FlexTRAK Series 2MB Material Handler Addendum Teaching Axis Positions
7-4 © 2023 Nordson Corporation
7.2 Bypass Mode
Material handling bypass mode is typically used for setup and teaching axis positions. Bypass mode
allows the technician to operate the MH with open access into the system via the front door.
?
NOTE This section is intended for maintenance personnel operating the FlexTRAK-2MB system
manually.
CAUTION! While operating the MH in bypass mode, exercise caution
around the moving components of the MH. Even though speeds
have been reduced, the potential danger of minor to moderate
injury to personnel can occur if proper procedures are not
followed.
Operating the FlexTRAK-2MB System in Bypass mode with the front door open disables safety
interlocks for the following hazards:
Table 7-1 Safety Hazards in Bypass Mode
Hazard Location Description
Pinch Point
Conveyor, Material
Handler System,
Process Chamber
A high-risk crushing hazard is created by the movement of the
conveyor.
Moving
Parts
Conveyor, Material
Handler System,
Process Chamber
A hand entanglement hazard is created by the movement of the
grippers. Keep hands away from this area unless the system
power is off.
Thermal
Hazard
Process Chamber
A high risk burn hazard is created by the process chamber.
Keep hands away from this area unless the system power is off
and heaters have cooled.
Radiation Process Chamber
Non-ionizing radiation hazard. RF generator produces RF
energy at levels that may cause burns.
Material handling bypass mode allows the MH to operate while the front door of the FlexTRAK-2MB
System is open. While in this mode, all five drives will operate at a fixed 25mm/sec. There is a key switch
that can only be accessed after opening the front door (Figure 4-1). Once the key is positioned to
BYPASS, the MH will override the front door interlock. At this point only the MH controls will function
at the reduced speeds. However, if the front door is then closed (interlock is made but still in bypass
mode) all FlexTRAK-2MB system controls will function. This mode is used during setup and teaching of
the system.

FlexTRAK Series 2MB Material Handler Addendum Teaching Axis Positions
© 2023 Nordson Corporation 7-5
7.2.1 Operating in Bypass Mode
To operate in bypass mode:
1. Open the FlexTRAK-2MB’s front door.
„ The Safety Cover Open dialog box opens (Figure 7-3).
Figure 7-3 Safety Cover Open Alarm
2. Turn the bypass key switch to BYPASS (Figure 7-4).
Figure 7-4 Bypass Key Switch

FlexTRAK Series 2MB Material Handler Addendum Teaching Axis Positions
7-6 © 2023 Nordson Corporation
3. Touch the MANUAL button to switch the MH to Manual mode (Figure 5-4).
4. Touch the MAINTENANCE button.
„ The Maintenance Master screen opens (Figure 5-5).
5. Touch the SHUTTLER button.
„ The Axis Status screen opens in Bypass Mode.
„ Notice that the axis speeds have all been reset to 25mm/sec and the note below the set
points reads "Interlock Bypass: Slow Speed Mode" (Figure 7-5).
Figure 7-5 Axis Status Screen in Bypass Mode
6. Click the MANUAL MODE button to enter manual mode.
„ The TEACH button becomes available after manual mode is entered.
7. Setup and teach the system using the FlexTRAK-2MB manual controls, see 7.1 Teaching
MH Axis Positions and 6.7 Manual Mode.
8. To exit bypass mode, open the FlexTRAK-2MB front door and turn the bypass key switch
to AUTO.