FlexTRAK Series 2MB Material Handler Addendum Introduction
© 2023 Nordson Corporation 1-5
Table 1-2 Rear View Feature Description
Item Name Description
1 Rear Access Panels
The Rear Access Panels allow access to system
components.
2 System Facilities Panel
The System Facilities Panel contains system facility
connection inputs, see 3.6 Connecting to the Facility.
3 Cooling Fans
The Cooling Fans regulate the temperature for system
components.
4
Seismic Feet (Optional)
The optional Seismic Feet can be used to level and secure
the system.
5 208V Power Connection
Power Connection for accessories (e.g., H
2
generator)
that will be turned off when the system is shut down.
6
Rear Emergency Machine Off
(EMO) Button
Pressing the rear EMO button completely turns off power
to the FlexTRAK-2MB system. When activated, the main
power connection to the system is disconnected via a
momentary action switch that sets the main power relay
to the OFF state and stops operation.
© 2023 Nordson Corporation 2-1
2 Safety
2.1 Overview
This section provides basic safety information for operating and servicing the FlexTRAK-2MB Material
Handler. This section covers the following topics:
System Use
Safety
Warning
Labels
Basic Safety Precautions and Practices
Basic Safety Precautions
Decommissioning
Safety Features
Disposal
Service Shutdown
Lifting and Transport Precautions
To further optimize safe system operation, precautions and recommended practices are included with the
procedures throughout this manual.
WARNING! Unsafe equipment conditions can result in personal injury or property damage.
Failure to properly operate and maintain the system in accordance with this
manual could cause the built-in safety features to be ineffective.
?
NOTE Safety is considered a joint responsibility between the original equipment manufacturer
(Nordson) and the end-user (owner). All safety precautions and practices should be in
accordance with local regulations and facility policy.
2.2 Facility Requirements
To ensure optimal performance and safety, it is necessary to install the plasma system in a facility that
meets or exceeds the requirements listed in the FlexTRAK Series Installation, Operations, and
Maintenance Manual. If you have any questions about facility requirements, please contact Technical
Support.
2.3 System Use
2.3.1 Intended Use
The FlexTRAK-2MB Material Handler is designed and built with safety as a top priority. If operated
according to the guidelines provided in this manual, the material handler should be safe to use. The
material handler is only suitable for the purpose described in this manual. Any other use is considered
improper. The manufacturer is not liable for any damage resulting from improper or unintended use.