S2-9 XXX Se ri es Dispensing Sys te m IOM Man ual Maintenance © 2023 Nordson C orporatio n 6-9 6.8 Compute r Ba tter y Reset To extend the life of th e batt ery, it is recommen ded th at you perform the f ollowing proced…

S2-9XXX Series Dispensing System IOM Manual Maintenance
6-8 © 2023 Nordson Corporation
6.7 Verifying Interlock Functionality
To verify interlock functionality:
1. Power on the dispensing system, see 4.3 Powering on the Dispensing System.
2. Start Fluidmove. Refer to the Fluidmove User Guide or Fluidmove Online Help.
3. Open the Fluidmove Jog window and use the position controls to move the dispensing head
in the X, Y, and Z-axes.
4. Open the dispensing area door.
Confirm that the light beacon is yellow and that there is a Fluidmove message
indicating that the dispensing area door is open.
5. Manually move the dispensing head in the X, Y, and Z-axes.
Confirm that the dispensing head moves freely (motors are not producing force).
6. While observing the dispensing head, close the dispensing area door and acknowledge the
Fluidmove error message.
Confirm that the dispensing head moves to the position it was in prior to opening the
dispensing area door.
WARNING! Immediately remove the dispensing system from service if the light beacon is not
yellow or the dispensing head does not move freely when the dispensing area
door is open.

S2-9XXX Series Dispensing System IOM Manual Maintenance
© 2023 Nordson Corporation 6-9
6.8 Computer Battery Reset
To extend the life of the battery, it is recommended that you perform the following procedure every six
months.
To reset the battery:
1. Click
Start > Control Panel on the Windows Taskbar.
The Windows Control Panel opens.
2. Select
Power Options > Power Manager > Launch Power Manager > Battery
Information > Battery Maintenance
.
The Battery Maintenance window opens (Figure 6-4).
3. Verify the settings are as shown in Figure 6-4.
Figure 6-4 Battery Maintenance Window

S2-9XXX Series Dispensing System IOM Manual Maintenance
6-10 © 2023 Nordson Corporation
4. Click on Perform Reset.
The Battery Gauge Reset window opens (Figure 6-5).
Figure 6-5 Battery Gauge Reset Window
5. Click on Continue.
The process may take several hours to complete. You should avoid using the computer