Spectrum+Operating+Manual.pdf - 第211页
S2-9 XXX Se ri es Dispensing Sys te m IOM Man ual Specifications © 2023 Nordson C orpor ation 9-3 9.3 Declara tion of Confor mity Th e machine described b elow complie s with the appropriat e basic safety a nd h ea lth r…

S2-9XXX Series Dispensing System IOM Manual Specifications
9-2 © 2023 Nordson Corporation
9.2 Facility Requirements
Table 9-1 Specifications
Facilities Requirements – All Models
System Footprint
Single station (width x depth):
Two stations (width x depth):
Three stations (width x depth):
600 x 1321 mm (23.6 x 52.0 in.)
850 x 1321 mm (33.5 x 52.0 in.)
1100 x 1321 mm (43.3 x 52.0 in.)
See 9.4 System Dimensions for system drawings.
Clearance Space
Requirement
915 mm
Power (Mains)
Adaptive power supply that accommodates supply voltages between
200-240 VAC, 47-63 Hz single phase.
Short Circuit Current Rating
(SCCR)
5 KA
Facility Circuit Requirement
1
S2-9XXX w/ 10A Power Supply
S2-9XXP or S2-9XXX w/ 30A Supply
10A
30A
(NEMA L6-30 Outlet Plug Provided)
Amperage (typical
Single lane Dual lane Per Heated Tool Total Amperage
4.6A 5.2A 4.7A
Base system +
heated tooling
Installation
(Over-Voltage Category)
Category II
Air Supply
2
Two air supplies: one with 3 CFM @ 100 psi for contact tooling, a second one
with 1 CFM @ 100 psi for the rest of the system (100 psi = 689 kPa, 6.8 atm).
Pneumatic Fittings 9084-23-14, 1/4-inch quick disconnect fittings
Air Consumption Application-dependent
House Vacuum (S2-9XXC) ~1 CFM @ 22 inHg max during purge routine
Energy Consumption
~6.0KWh max (with heat)
~0.4KWh max (without heat)
System Noise
<70 dBA, 76 db peak @ 1 M (does not include valve operation noise)
Environmental Conditions
(Operation and Storage)
Shipping: 5-55 °C, 5-90% RH
Operating: 18-28
°
C, 5-90% RH
Ventilation
Downdraft or updraft
Vent port diameter: 147.6 mm (5.8 in.)
NOTE: Contact the factory regarding impingement heat applications:
100 cfm from the exhaust port may be required.
System Weight
3
Single station:
Two stations:
Three stations:
377 kg. (31 lbs)
399 kg. (880 lbs)
422 kg. (930 lbs)
Crate Dimensions
1930 x 1321 x 1981 mm (76.0 x 52.0 x 78.0 in.)
Crated Weight
590 kg (1300 lbs)
Standards Compliance
SMEMA, CE, SEMI-S2, SEMI-S8, NFPA 79
1
10A power manager may use either 120VAC or 240VAC input power supply
2
S2-9XXX/9XXP system when configured with regular impingement tools: requires one air supply with 9 CFM @ 100 psi for
impingement air and a second air supply with 1 CFM @ 100 psi for the rest of the system. S2-9XXX/900P system when configured
with the high-flow impingement option requires one air supply with 14 CFM @ 100 psi for impingement air and a second air supply
with 1 CFM @ 100 psi for the rest of the system.
3
Basic weight without options; actual system weight will depend on the specific configuration.

S2-9XXX Series Dispensing System IOM Manual Specifications
© 2023 Nordson Corporation 9-3
9.3 Declaration of Conformity
The machine described below complies with the appropriate basic safety and health requirements of the
listed directives based on its design and type, as delivered by Asymtek. In case of alteration of the
machine, this declaration may lose its validity.
Manufacturer’s Name:
Manufacturer’s Address:
Asymtek
2747 Loker Avenue West
Carlsbad, CA 92010-6603 USA
Authorized Representative in the EU:
“Technical Manager Europe” is authorized to compile technical file.
Authorized Representative Address
in the EU:
Nordson B.V.
Beukelsdijk 2
5753 PA Deurne, Netherlands
Machine/Machine Part Description:
General Industrial Machinery
Type of Equipment:
Automated Dispensing System
Product Series Name:
S2-9XXX Series
Model Number:
Serial Number:
Year of Manufacture:
Applicable EU Directives:
2006/42/EC
Machinery Directive and all applicable amendments
2014/30/ECU
EMC Directive and all applicable amendments.
Applicable Harmonized Standards:
EN 60204-1:2006/AC:2010 Safety of Machinery Electrical Equipment of Machines
Part 1: General Requirements
EN ISO12100:2010 Safety of Machinery General Principles for Design Risk Assessment
and Risk Reduction
EN 61000-6-2:2005/AC:2005
Electromagnetic Compatibility-Immunity for Industrial Environments
EN 61000-6-4:2007/AC:2011 Electromagnetic Compatibility-Emission Standard for Industrial
Environments
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directives
and Standards.
Signature:
Date:
(Name) Vice President, Asymtek
Place of Issue: Carlsbad, CA, USA

S2-9XXX Series Dispensing System IOM Manual Specifications
9-4 © 2023 Nordson Corporation
9.4 Specifications
9.1.1 Laser Height Sensor Specifications
Table 2-2 Laser Height Sensor Specifications
Laser Height Sensor
Small Dot Laser Height
Sensor
Laser Height Sensor
for Transparent, Reflective
Surfaces
Classification
Class I Laser Product
Class I Laser Product
Class 2 Laser Product
Light Source
Semiconductor Laser
220 µW, 630 nm (red)
Semiconductor Laser
220 µW, 630 nm (red)
Semiconductor Laser
1 mW, 670 nm (red)
Maximum Output
220 µW
220 µW
1.0 mW
Emitted Wavelength
630 nm
630 nm
670 nm
Spot Diameter
700 x 200 µm at a reference
distance of 30 mm
200 µm round
7 µm at reference distance of
30 mm
Reference Distance
and Range
30 mm ± 10 mm
(1.2 in. ± 0.4 in.)
30 mm ± 10 mm
(1.2 in. ± 0.4 in.)
30 mm ± 1 mm
(1.2 in. ± 0.04 in.)
Environmental
Range
0 to 55 °C
0 to 85% RH
0 to 55 °C
0 to 85% RH
0 to 55 °C
0 to 85% RH
Ambient Light
4,000 lux max
4,000 lux max
10,000 lux max