Spectrum+Operating+Manual.pdf - 第160页

S2-9 XX X Se ri es Disp ensi n g Syst em IOM Man ual Parts Replacement 8-8 © 2023 Nordson Corporatio n Ite m Description Item Desc ription 1 Sc ale Lid 4 Scal e P edestal 2 Sc ale C up 5 S cre ws (2) 3 Br eez e S hield 6…

100%1 / 222
S2-9XXX Series Dispensing System IOM Manual Parts Replacement
© 2023 Nordson Corporation 8-7
To install the service station (Figure 8-3):
1. Remove and set aside the dispense tile and purge station lid.
2. Place the service station into the service station bracket.
3. Place a bubble level onto the service station.
4. Adjust the service station height, see 5.11 Adjusting the Service Station Height.
5. When level, tighten the three (3) screws securing the service station to the service station
bracket.
If needed, fine leveling can be
achieved by adjusting the set screws on the service
station.
6. Remove the bubble level from the service station.
7. Reinstall the dispense tile and purge station lid.
8. Connect the pneumatic and electrical connections to the service station.
9. Install the dispense station cover, see 8.8 Removing and Installing the Dispense Station
Cover.
10. Close the dispensing area door.
8.11.2 Replacing the Scale Assembly
To remove the scale assembly:
1. Perform a service shutdown, see 2.14 Service Shutdown.
2. Open the dispensing area door.
3. Remove the dispensing station cover, see 8.8 Removing and Installing the Dispense Station
Cover.
4. Remove the dispense station cover from the dispensing system.
5. Remove the service station, see 8.9.1 Replacing the Service Station.
6. Remove the scale lid, scale cup, breeze shield cover, and scale pedestal from the scale
(Figure 8-4
).
7. Remove the two (2) screws securing the service station bracket to the rail.
8. If a scale shutter is installed, disconnect the pneumatic connections from the scale assembly.
9. Disconnect the electrical connection from the scale assembly.
S2-9XXX Series Dispensing System IOM Manual Parts Replacement
8-8 © 2023 Nordson Corporation
Item
Description
Item
Description
1 Scale Lid 4 Scale Pedestal
2 Scale Cup 5 Screws (2)
3 Breeze Shield 6 Service Station Bracket
Figure 8-4 Replacing the Scale Components and Service Station Bracket
10. Remove the four (4) screws securing the scale assembly to the dispensing system
(Figure 8-5).
11. Remove the scale assembly from the dispensing system.
Item
Description
1 Kit, FRU, S2-9XX Scale Assy (Item 30)
2 Screws (4)
Figure 8-5 Replacing the Scale Assembly
6
5
2
3
4
5
1
1
2
2
S2-9XXX Series Dispensing System IOM Manual Parts Replacement
© 2023 Nordson Corporation 8-9
To install the scale assembly:
1. Install the scale assembly to the dispensing system with four (4) screws (Figure 8-5).
2. Torque the four (4) screws to 9.8 Nm (87 in-lbs).
3. Install the scale pedestal, breeze shield cover, scale cup, and scale lid onto the scale
assembly (Figure 8-4).
4. Install the two (2) screws securing the valve bracket to the rail.
5. Place a bubble level on top of the scale lid.
6. Loosen, do
not remove, the three (3) securing screws (Figure 8-6).
7. Adjust the three (3) leveling screws to level the scale assembly.
The scale lid should be flush or 2 mm above the conveyor rail.
8. Tighten the three (3) securing screws securing the scale assembly while ensuring the scale
remains level.
9. Remove the bubble level from the top of the scale lid.
10. If a scale shutter is installed, connect the pneumatic connect
ions to the scale assembly.
11. Connect the electrical connection to the scale assembly.
12. Install the service station, see 8.9.1 Replacing the Service Station.
13. Close the dispensing area door.
Item
Description
1 Kit, FRU, S2-9XX Scale Assy (Item 30)
2 Leveling Screws (3)
3 Securing Screws (3)
Figure 8-6 Leveling the Scale Assembly
1
3
3
2
3
2