S2-9XXX Series Dispensing System IOM Manual Calibration and Adjustment
5-6 © 2023 Nordson Corporation
3. Click on Calibrate.
The Calibration window opens (Figure 5-5).
Figure 5-5 Calibration Window
4. Position the camera over a fiducial and adjust the light level to obtain a good image
contrast. Refer to the Fluidmove User Guide or Fluidmove Online Help.
5. If the image is not in focus, focus the camera, see 5.4 Focusing the Camera.
6. Click on
Next.
7. Verify that the fiducial image is centered and click on
Next.
The vision system will take a snap image of the fiducial.
8. If the fiducial is acceptable, select
Next. If not, select Prev and define a new fiducial.
NOTE The fiducial should fit inside the green square on the camera image.
9. After the camera calibration sequence is complete, verify that the X and Y values are
relatively close (within 10 increments) of each other. If there is a large difference, repeat the
calibration process and define a new fiducial.
10. If the results are satisfactory, select
Done to save the calibration results.
NOTE Machine Offsets must be performed after calibrating the camera. Refer to the Fluidmove
User Guide or Fluidmove Online Help for more information.
S2-9XXX Series Dispensing System IOM Manual Calibration and Adjustment
© 2023 Nordson Corporation 5-7
5.6 Calibrating the Scale
NOTE The scale should only need to be calibrated once during installation. However, if the scale
is moved, recalibration is recommended.
Tools and Materials Needed:
50g Calibration Weight
Screwdriver
Latex gloves or tweezers
To calibrate the scale:
1. Power on the dispensing system, see 4.3 Powering on the Dispensing System.
2. Start Fluidmove. Refer to the Fluidmove User Guide or Fluidmove Online Help.
3. Select
Configuration > Setup Scale from the Main Window.
The Scale Setup window opens (Figure 5-6).
4. Select “SART-WZ” from the Type pull-down menu.
Figure 5-6 Setup Scale - Scale Operations Tab
S2-9XXX Series Dispensing System IOM Manual Calibration and Adjustment
5-8 © 2023 Nordson Corporation
5. Click on the Advanced tab (Figure 5-7).
Figure 5-7 Setup Scale - Advanced Tab
6. Verify that the calibration weight is set to 50 and click on Calibrate.
Fluidmove will prompt you to place the weight on the scale.
7. Remove the scale cover and cup (Figure 5-8).
Item
Description
1
Scale Cover (Item 30)
2
Scale Cup (Item 30)
3
Pedestal (inside)
Figure 5-8 Removing the Scale Cover and Cup
1
2
3