Aimex3C系统手册.pdf - 第282页
8. 各种功能的设定和管理 SYS-AIMEX3C-007S0 266 AIMEX III/AIMEX IIIc 系统手册 4. 在各个项目中进行 必要的设置。有关设定内容的详细 情况,请参照设定画面下方的记述 。 5. 完成所有的设定项 目后,请单击 [Send to Machine]。 6. 结束所有的设定变 更的传输后,单击 [Close]。 Optional unit settings Tape cutt er /waste t…

SYS-AIMEX3C-007S0 8. 各种功能的设定和管理
AIMEX III/AIMEX IIIc 系统手册
265
8.3 设定模组功能
只有被选模组内反映出此处设置的内容。
1. 选择要进行设置的模组 ( 可复选 )。
2. 从 [ 菜单 ] 中单击 [Module Configuration] 后,就会显示模组功能设定画面
3. 在 [ 分类 ] 的选择箱内选择设置项目后,一览的显示内容将变更。
分类 设置项目
Operation settings Premounted parts height settings
Parts reject operation
Nozzle defect detection
Nozzle statistical error settings
Interval stop setting
Read condition settings for Fujitrax Profiler Panel IDs
Breakdown operation settings
Placement point check function
Auto recovery function
Rescue function when the recovery limit is reached setting
Use Auto Splicing Unit
LCR checks
DX Protector
Panel conveyance settings Panel stopping position correction (module)
Panel stop offset
Tray unit settings Tray Unit LT/LTW, M pickup pressure setting
Tray Feeder Unit L, M pickup pressure setting
30SYS-1151-E
oNnLLVIq
oNnLLVIq
Downloaded at 2017/10/30 17:10:21 by 307B1555 DL#XAxe7m6U
Downloaded at 2017/10/30 17:10:21 by 307B1555 DL#XAxe7m6U

8. 各种功能的设定和管理 SYS-AIMEX3C-007S0
266 AIMEX III/AIMEX IIIc 系统手册
4. 在各个项目中进行必要的设置。有关设定内容的详细情况,请参照设定画面下方的记述。
5. 完成所有的设定项目后,请单击 [Send to Machine]。
6. 结束所有的设定变更的传输后,单击 [Close]。
Optional unit settings Tape cutter/waste tape box unit settings
Auto backup pin settings
Dip settings Dipping
Flux unit settings
Calibration settings Feeder pickup height setting
Thermal measurement for panels that require production
over a long time
Placement angle measurement
Hybrid calibration
Detect foreign objects on hybrid calibration jig parts
Reduce Hybrid Calibration Time
Thermal expansion correction when operating Part-camera-
less employment
Provisional measurement without matrix data function
OFC thermal expansion measurement
Measurement for improving part pickup
(This setting is only for H24/H12HS/V12 heads.)
Nozzle diameter
Remote command operation Mark camera image capture
分类 设置项目
oNnLLVIq
oNnLLVIq
Downloaded at 2017/10/30 17:10:21 by 307B1555 DL#XAxe7m6U
Downloaded at 2017/10/30 17:10:21 by 307B1555 DL#XAxe7m6U

SYS-AIMEX3C-007S0 8. 各种功能的设定和管理
AIMEX III/AIMEX IIIc 系统手册
267
8.3.1 吸嘴统计异常功能设定
统计吸嘴检查状况,如果吸取失误超出设定次数,将该吸嘴切换到别的吸嘴的功能。
• [Change nozzles when statistical errors occur]:[Change nozzles]
• [Error count to decide statistical nozzle errors]:成为错误的吸取次数
将该功能设定为有效后,请在吸嘴置放台内安装预备吸嘴。
8.3.2 模组故障时的运用功能设定
模组内的单元或者伺服马达发生故障时,通过只运用其搬运轨道,也能够继续生产线的生产。
• [Breakdown operation mode]:[Conveyor only]
こ为了使该设置变为有效,请在主系统上编辑 Job。将发生故障的模组上装有的供料器以及贴装坐标重新
分配到其他模组上。
30SYS-0212E
30SYS-0188E
oNnLLVIq
oNnLLVIq
Downloaded at 2017/10/30 17:10:21 by 307B1555 DL#XAxe7m6U
Downloaded at 2017/10/30 17:10:21 by 307B1555 DL#XAxe7m6U