3OM-1050-002.pdf - 第229页
01 10-003 5 - 2 AFO01EDTP 1.2 Outline of Each Item 1 . 2 Outline of Each Item The system setting is composed of the following items. SYS DA T A This enables the operator to set the device offset data, the automatic opera…

1. Outline of System Setting
The system setting session enables you to set up the machine system,
specify the nozzle-related items, and specify the machine properties.
1.1 Composition of System Setting
The system setting is composed of the following items.
SYSTEM
Tabs (Tab Sheets) Reference Item Nos.
"System" Window Device Offset (3.2)
Auto Operation (3.3)
Configuration Setup (3.4)
"Nozzle Data" Window Placement Head/ (4.1)
Nozzle Data
Nozzle Data (4.2)
"MACH SETUP" Display Set (5.1)
Window
Password (5.2)
Date & Time Dt (5.3)
Others (5.4)
Fig. 3E1
01 10-003 5 - 1
AFO01EDTP
1. Outline of System Setting

01 10-003 5 - 2 AFO01EDTP
1.2 Outline of Each Item
1.2 Outline of Each Item
The system setting is composed of the following items.
SYS DATA
This enables the operator to set the device offset data, the automatic
operation data, the light tower, and the alarm system.
NOZ DATA
This enables the operator to set the placement head/nozzle data and
the nozzle data.
MACH SETUP
This enables the operator to set the screen saver function and specify
the unit of length, a language, a password, date and time, etc.

2. Navigations in "SYSTEM" Window
2.1 Display of Each Window
2.1.1 "System" Window
The following describes how to open the "System" window.
• Window Layout
(1) Press the [SYSTEM] button on the main menu bar. The "SYS SEL"
menu opens.
Fig. 3E2
(2) Press the [SYS DATA] button.
The "System" window opens.
Fig. 3E3 "System" Window
0301-005 5 - 3
AFO01EDTP
2.1 Display of Each Window