0301-005 5 - 4 5 AFO01EDTP *5 Feeder message rate Error counts [times], # of picks [times] Set the parameters to show the feeder slot No. (Fdr . No.) of the tape feeder whose pickup rate has deteriorated during automatic…

100%1 / 321
0301-005 5-44 AFO01EDTP
*3 Closed loop Max counts [times]
(Not Available)
*4 Auto feeder axis adjustment set
# of picks [times], (X) adjustment [%], (Y) adjustment [%]
Set the sensitivity parameters which follow up the data learned by
using the statistical method in the feeder (B) offset data.
New "FDR. (B) OFFSET" = Old "FDR. (B) OFFSET" +
(mean of deviation obtained n times) * Coefficient
# of picks [times]
Set the total number of collected samples when data is updated or
changed.
(a) The data input range is "1 to 10".
(b) The standard value is "3".
(X) adjustment [%]
Set the feedback coefficient of the mean of the feeder axis’ X-direc-
tion deviation.
(a) The data input range is "10 to 100%".
(b) The standard value is "50%".
(Y) adjustment [%]
Set the feedback coefficient of the mean of the feeder axis’ Y-direc-
tion deviation.
(a) The data input range is "10 to 100%"
(b) The standard value is "50%"
3.3 "Auto Operation" Tab
0301-005 5-45 AFO01EDTP
*5 Feeder message rate
Error counts [times], # of picks [times]
Set the parameters to show the feeder slot No. (Fdr. No.) of the tape
feeder whose pickup rate has deteriorated during automatic opera-
tion.
When the number of picks has reached the specified value, the
parameter in the "Error counts [times]" text box is cleared.
When the number of pickup errors has reached the specified error
counts before the number of picks reaches the specified number of
picks, a warning message is issued as machine information.
(a) The number of picks and pickup errors is managed
for each feeder slot No. but the parameters in the "Er-
ror counts [times]" and "# of picks [times]" text boxes
are equally reflected on every feeder slot No.
(b) The data input range is "0 to 9999" (times) for both
"Error counts [times]" and "# of picks [times]".
(c) When "0" (zero) is set for "# of picks [times]" and "Er-
ror counts [times]" or the parameter in the "Error counts
[times]" text box is larger than the parameter in the "#
of picks [times]" text box, no warning message is is-
sued.
3.3 "Auto Operation" Tab
*6 Nozzle message rate
Error counts [times], # of picks [times]
Set the parameters to show the nozzle No. whose pickup rate has
deteriorated during automatic operation.
When the number of picks has reached the specified value, the
parameter in the "Error counts [times]" text box is cleared.
When the number of pickup errors has reached the specified error
counts before the number of picks reaches the specified number of
picks, a warning message is issued as machine information.
(a) The number of picks and pickup errors is managed
for each feeder slot No. but the parameters in the "Er-
ror counts [times]" and "# of picks [times]" text boxes
are equally reflected on every feeder slot No.
(b) These parameters are not reflected on the automatic
nozzle bypass function. This is only for warning and
guidance.
(c) It is recommended that a comparatively short span be
specified.
(d) This function is provided to survey and avoid machine’s
malfunctions which may be caused during the start-
up operation of the machine.
(e) The data input range is "0 to 9999" (times) for both
"Error counts [times]" and "# of picks [times]"
(f) When "0" (zero) is set for "# of picks [times]" and "Er-
ror counts [times]" or the parameter in the "Error counts
[times]" text box is larger than the parameter in the "#
of picks [times]" text box, no warning message is is-
sued.
*7 Finished product interval
Mode, Interval [times]
This is one of the progress information messages displayed as ma-
chine information. When "Monitor" is set in the "Mode" text box, the
number of processed products can be monitored every time the
number of processed P.C.B.’s reaches the specified parameter in
the "Interval [times]" text box.
When "0" (zero) is set in the "Interval [times]" text box, the
number of processed products cannot be monitored.
0301-005 5-46
AFO01EDTP
3.3 "Auto Operation" Tab