2 . 5 Placement Data Fig. 3B85 Edit Window (Example) (C01) Placement Data Un (C01_01) Placement Data Unit Designation Select one of the following tabs (placement data groups) in one pattern program. U 01 : First Placemen…

100%1 / 321
(B01_07) Feeder Alternate
Select "Enable" or "Disable" to determine whether or not the feeder
alternate function should be used.
Disable : The feeder alternate function is not used.
Enable : The feeder alternate function is used.
(B01_08) Fdr No.
When "Enable" is selected for the feeder alternate function, set the
destination feeder No. (Fdr No.) of the feeder that will work in place of
the feeder where a component shortage error has occurred.
2.4 Placement Feeder Location Data
0210-005 2-44 AFO01EDTP
Feeder Alternate
Fig. 3B83
Disable
000 (000)Fdr No.
Fig. 3B84
2.5 Placement Data
Fig. 3B85 Edit Window (Example)
(C01) Placement Data Un
(C01_01) Placement Data Unit Designation
Select one of the following tabs (placement data groups) in
one pattern program.
U01 : First Placement Data Group
U02 : Second Placement Data Group
Un : Up to 99 placement data groups can be specified.
Fig. 3B86 Example of Placement Data (TCM-X200)
(a) "U01" is used in normal cases.
(b) The operation and feeder location data are used commonly.
(c) Refer to "2.1Types of P.C.B.’s and Required Data" and "Ex-
emplified Data Creation" for details.
(d) The placement coordinate reference of TCM-X100 is "Rear
Left".
U02
U01
Fiducial Marks
Placement Coordinate Reference Point
2.5 Placement Data
0210-004 2-45 AFO01EDTP
(C02) Placement Data (P-data)
(C02_01) Unit Control
Select one of the following options to determine whether the selected
placement data (U01, U02, ..... Un) should be used.
In normal cases, select "Placement".
Placement : The placement data of the selected unit (group) be-
comes valid.
Bypass : The placement data of the selected unit (group) be-
comes invalid.
Offset X [mm] and Offset Y [mm]
Set the offset values for all placement coordinates X and Y and the
recognition coordinates of the unit P.C.B. in the placement data (P-
data).
Unit: mm
(a) Use "000.000" (zero) in normal cases.
(b) Note that these offset values do not give any effect to the
coordinates (X [mm] and Y [mm]) of "(A02_02) P.E.C.
recognition mode global".
Offset Z [deg]
Set the offset value for all placement angles (Z=Theta) in the place-
ment data (P-data).
Unit: °(degree)
Use "000.00" (zero) in normal cases.
2.5 Placement Data
0301-006 2-46 AFO01EDTP
Placement
Unit Control
Fig. 3B87
Fig. 3B88
Offset X [mm]
Offset Y [mm]
+000.000
+000.000
Fig. 3B89
+000.00
Offset Z [deg]