3OM-1050-002.pdf - 第79页

3. Example of Pattern Program Creation Described on the following pages are the examples of pattern programs to be created. The example of data creation is based on TCM-X200. As for TCM-X100, the placement coordinate ref…

100%1 / 321
(C03_06) B-X [mm], B-Y [mm]
When "Optional" is set in the "Unit P.C.B. B.B.R." text box, it is re-
quired to set the coordinates of each unit P.C.B. B.B.R. mark (each
bad mark) based on the placement coordinate reference N
0
.
Unit: mm
Fig. 3B115
(a) Refer to "2. Various Functions" in "Section 2" of "Volume 2: Opera-
tion (Supervisor)" for the unit P.C.B. B.B.R. detection function.
(b) Do not set any coordinates in the text boxes of the last line (last step
No.).
Keep them as "000.000".
Placement Coordinate
Reference (N
0
)
Bad Mark of Pattern 1
Bad Mark of Pattern 2
Bad Mark of Pattern 3
Bad Mark of Pattern 4
Pattern 4
(B-X
4
, B-Y
4
)
Pattern 3
(B-X
3
, B-Y
3
)
Pattern 2
(B-X
2
, B-Y
2
)
Pattern 1
(B-X
1
, B-Y
1
)
Placement Coordinate
Reference (N
0
)
Bad Mark of Pattern 1
Bad Mark of Pattern 2
Bad Mark of Pattern 3
Bad Mark of Pattern 4
Pattern 4
(B-X
4
, B-Y
4
)
Pattern 3
(B-X
3
, B-Y
3
)
Pattern 2
(B-X
2
, B-Y
2
)
Pattern 1
(B-X
1
, B-Y
1
)
TCM-X100
TCM-X200 TCM-X300
2.5 Placement Data
0307-005 2-57 AFO01EDTP
Fig. 3B114
B-X [mm]
B-Y
[mm]
000.000
000.000
3. Example of Pattern Program Creation
Described on the following pages are the examples of pattern programs
to be created.
The example of data creation is based on TCM-X200.
As for TCM-X100, the placement coordinate reference is "Rear
Left ".
Single Pattern
Single Pattern (P.E.C. Recognition Function Enabled)
Repetitive Patterns
Repetitive Patterns (Unit P.C.B. B.B.R. Enabled)
Repetitive Patterns (Unit P.C.B. B.B.R. Function Enabled)
Repetitive Patterns (Block Sorting Enabled)
Repetitive Patterns (Polar Coordinate Conversion Function)
Multi-Model Repetitive Patterns
3.1 Single Pattern
(1) Information on Pattern Program Creation
P.C.B. Size
Fig. 3B116
Packaged Posture and IDs of Components
No. Component ID
*1 TANA3216B0- - -
*2 TR2012-3B0SANL2
*3 SOP008-B02SAN
Fig. 3B117
0110-003 2-58
AFO01EDTP
3. Example of Pattern Program Creation
250 mm
1.6 mm
P. C. B .
330 mm
P.C.B. Flow Direction
*3
*2
*1
User Direction of
Component Feed
0210-004 2-59 AFO01EDTP
Placement Coordinate and Angles (Z=Theta)
Fig. 3B118
(2) Creation of Operation Data
P.C.B. Data
Table 3B18
Placement Coordinate Reference Point
X
3
Y
3
X
2
Y
2
X
1
Y
1
Alternate mode Disable
Alternate carriage data
priority processing
Feeder No. offset +000
X/Y table accel des Full Speed
F1 accel des Full Speed
F2 accel des Full Speed
F3 accel des Full Speed
F4 accel des Full Speed
Recovery U-N Disable
regulation Block Disable
Unit P.C.B. B.B.R.
Mode Disable
Image
Component
prechuck
Sequence
Overall Mode Disable
P.C.B. B.B.R.
X [mm]
Y [mm]
P.C.B. size
P.C.B.
origin offset
X [mm]
Y [mm]
T [mm]
X [mm]
Y [mm]
Z=Theta [deg]
P.C.B. height offset [mm]
P.C.B. Positioning Reference
Pre-Placed component thickness [mm]
Placement mode
P.C.B. transfer speed
Placement data sorting
Feeder standby position
330.000
250.000
1.600
+00.000
+00.000
+0.00
+00.000
Front Right
00.000
Placement
Standard
Standard
000
3.1 Single Pattern