0301-006 5 - 5 7 AFO01EDTP *15 Output Conveyor P .C.B. Out Set "Disable" or "Enable" in the text box to determine whether or not a disengaged P .C.B. should be detected in the output conveyor sec- tio…

*11 P.C.B. output buffer position
Set "Outlet" or "Middle" as the P.C.B. buffer position for P.C.B. transfer
actions.
Fig. 3E44 and Fig. 3E45 show that the P.C.B. flow direc-
tion is "From Left to Right".
When the P.C.B. flow direction is "From Right to Left", the
reverse actions take place, compared with the figures.
Actions taken when "Outlet" is selected
Fig. 3E44
Action taken when "Middle" is selected
Fig. 3E45
*12 X/Y conveyor reverse stroke [mm]
Set the reverse stroke of the chute (X/Y) conveyor required when
the P.C.B. is transferred.
When the P.C.B. is fed over to the chute in the transfer operation,
the transfer claw might be kept away from the P.C.B.
The P.C.B. positioning will be completed normally by rotating the
chute (X/Y) conveyor in the reverse direction as much as the speci-
fied value to make the P.C.B. completely in contact with the transfer
claw.
Default (Value at Shipment): 5.0 mm
*13 P.C.B. clamp timer [sec]
Set the P.C.B. clamp timer in the text box.
*14 Pass mode select
One of the following options can be selected as a way to pass a
P.C.B.
Conveyor : The conveyor is activated to pass a P.C.B.
Transfer claw : The conveyor and the P.C.B. transfer claw are
activated to pass a P.C.B.
0307-006 5-56 AFO01EDTP
3.3 "Auto Operation" Tab

0301-006 5-57 AFO01EDTP
*15 Output Conveyor P.C.B. Out
Set "Disable" or "Enable" in the text box to determine whether or not
a disengaged P.C.B. should be detected in the output conveyor sec-
tion.
*16 Furnace Signal Check
Set "Disable" or "Enable" in the text box to determine whether or not
the furnace signal check function should be used.
When "SMEMA" is set in the "Input mode" or the "Output
mode" text box, this function does not work.
*17 P.C.B. exist signal check
It must be determined whether or not the P.C.B. exist signal should
be checked.
No Check : The P.C.B. exist signal is not checked.
Input & Output : The P.C.B. exist signals from the input/output
machines are checked.
Input : Only the P.C.B. exist signal from the input ma-
chine is checked.
Output : Only the P.C.B. exist signal from the output ma-
chine is checked.
(a) When a parameter other than "No Check" is set in the
"P.C.B. exist signal check" text box, the P.C.B.’s on
the conveyors of the input and output machines are
detected and the automatic setup actions, etc., are
restricted.
(b) When "SMEMA" is set in the "Input mode" or the "Out-
put mode" text box, this function does not work.
*18 Transfer conveyor reverse speed
When a P.C.B. is transferred, the rotation of the conveyor is re-
versed to bring the P.C.B. close to the transfer claw. The speed of
the reverse rotation can be specified in this text box.
Select one of the following options.
Full Speed, 10%Decr, 20%Decr, 30%Decr, 40%Decr,
50%Decr, 60%Decr, 70%Decr, 80%Decr, 90%Decr
3.3 "Auto Operation" Tab

3.4 "Configuration Setup" Tab
3.4.1 "Light Tower Setup" Tab
• Sheet Layout
When the "Light Tower Setup" tab is pressed in the "Configuration Setup"
tab sheet, the following tab sheet appears.
Fig. 3E46 "Light Tower Setup" Tab Sheet
• Sheet Composition
*1 Data Name
Displayed are the items for which the colors (red, yellow, and green)
of the tower lights and the types of alarm sounds should be speci-
fied.
*2 Red, Yellow, Green
Set "On", "On & Off", or "Off" in each text box to specify the colors
(red, yellow, and green) of the tower lights.
*3 Buzzer
Set "Off", "Intmt Snd", "Cont Snd", or "Optl Snd" in each text box to
specify the types of alarm sounds.
The desired sound patterns can be made, using the "Alarm Setup"
tab sheet.
*1
*2
*3
*4