N7201A652E.pdf - 第226页

NPM- TT2 EJM1EE-MB -03O-02 ADR (address) Feeder address. ( → P.3-2-3 -1 ) 3-2-8 -1 C A B D E F G Produc- tion informa- tion Operating procedure 3-2-8 No Data number. Head The nozzle position numbe r at which error occurr…

100%1 / 512
NPM-TT2 EJM1EE-MB-03O-02
Production
3-2-7-2
NPM-TT2 EJM1EE-MB-03O-02
ADR (address)
Feeder address.
(P.3-2-3
-1)
3-2-8-1
C
A
B
D
E
F
G
Produc-
tion
informa-
tion
Operating procedure
3-2-8
No
Data number.
Head
The nozzle position number at which
error occurred in the placement head.
H
I
Date/Time
TBL (table)
The table on which the error occurred.
Error kind
Nzl
The nozzle number at which error
occurred.
Deletes all the error histories.
Shows the previous or next table.
Vacuum sensor error
history
You can check up to 50 records of vacuum sensor error information, that occurred during automatic
production, in reverse chronological order.
HB I
DC E F GA
1
NPM-TT2 EJM1EE-MB-03O-02
3-2-8-2
C
A
B
D
Returns to the previous screen.
X [mm]/Y [mm]
The coordinates on which the error
Occurred.
E
F
Turn
The turn between a feeder and a PCB
when error occurred.
PCB
The mounting order in the turn in which
the error occurred.
For one PCB,
0 is displayed.
For two PCBs,
0: first PCB, 1: 2nd PCB.
JudgeVal
Vacuum error judgment value.
(8-bit tones display)
Actual
Vacuum actual value.
(8-bit tones display)
1
(Displays detailed error information)
D
B C E FA
Production