N7201A652E.pdf - 第404页
NPM- TT2 EJM1E E-MB-05O-05 Unit setting Action par ameter setting 5 5-1-2 -9 Setting information 8 Operating procedure 5-1-2 ■ Feeder (3/6) Type Item Description Initial value Setting range Determine Tape cutting lengt h…

NPM-TT2 EJM1EE-MB-05O-05
5-1-2-8
Setting information 7
System
administration
Type Item Description Initial
value
Setting
range
Mechanic
4mm Limit of the No2
origin offset(-)[mm]
The minus limit area of the second origin
offset on the 4mm feeder is set to narrower
when component supply condition is
degraded.
-1.0 -1.0 to 0.0
4mm Limit of the No2
origin offset(+)[mm]
The plus limit area of the second origin
offset on the 4mm feeder is set to narrower
when component supply condition is
degraded.
1.0 0.0 to 1.0
Pickup position teach
count [cnt]
The recognition retry count if pocket
recognition error occurs
11 to9
Timer
BowlFeeder Vibration
time(Std)[ms]
Bowl Feeder vibration time (Std) 250 0 to 30000
BowlFeeder Vibration
time(Mid)[ms]
Bowl Feeder vibration time (Mid) 500 0 to 30000
BowlFeeder Vibration
time(Slow)[ms]
Bowl Feeder vibration time (Slow) 1000 0 to 30000
Verification2 limit time
of pulling out and
inserting[s]
With “Verification 2” turned ON and set to
any value other than “0”, a feeder is not
required to be verified again if you pull out
or insert the feeder within the setting time
frame.
●Re-verification is required when the value
is “0”.
00 to60
Determine
Bad feeder error
rate [%]
This is a criterion used to judge whether
feeders are good or bad.
The feeder whose error rate exceeds the
set value is considered a bad feeder, and
the machine stops on error.
20 0.1 to 100
Parts empty pickup
error times (8 mm)
[piece]
If the set number of pickup errors occurs
successively in the 8 mm wide reel, the
machine
judges it as a shortage.
15 3 to 30
Parts empty pickup
error times (over 12
mm) [piece]
If the set number of pickup errors occurs
successively in the 12-mm-or-more wide
reel,
the machine judges it as a shortage.
33 to 30
■Feeder (2/6)

NPM-TT2 EJM1EE-MB-05O-05
Unit
setting
Action parameter
setting 5
5-1-2-9
Setting information 8
Operating procedure
5-1-2
■Feeder (3/6)
Type Item Description Initial
value
Setting
range
Determine
Tape cutting length (F)
[mm]
Setting value used to cut tape during
automatic operation. Tape is cut when the
longest empty tape on the front table
exceeds this value.
100
10.0 to
2000.0
Tap cutting length (R)
[mm]
Setting value used to cut tape during
automatic operation. Tape is cut when the
longest tape on the rear table exceeds this
value.
100
10.0 to
2000.0
Feeder mainte qty
(8 mm) [ten thousand]
When the maintenance count has reached
this value with feeder maintenance warning
ON, operation cannot be continued.
100 1 to 500
Feeder mainte qty
(12/16 mm) [ten
thousand]
100 1 to 500
Feeder mainte qty
(24/32mm)
[ten thousand]
100 1 to 500
Feeder mainte qty
(44/56mm)
[ten thousand]
100 1 to 500
Feeder mainte qty
(72mm)
[ten thousand]
100 1 to 500
Feeder mainte qty
(88/104/120mm) [ten
thousand]
100 1 to 500

NPM-TT2 EJM1EE-MB-05O-05
Setting information 9
System
administration
5-1-2-10
■Feeder (4/6)
Type Item Description Initial
value
Setting
range
Determine
Feeder mainte
warning rate[%]
The number of times a feeder has been
maintained exceeds the quantity obtained by
“Feeder mainte qty x Setting value”, a feeder
maintenance warning is displayed.
●If 100% is set, only warning is displayed.
100 0 to 100
Pickup position
reteaching
deviation [%]
When the joint part of splicing is detected
and fed at once, and pickup position
automatic teaching is carried out, if the chip
size of MAX L and MAX W exceeds the
value (%) automatic teaching retry is carried
out as recognition result out of area error.
This is used only if the joint part of splicing is
detected and fed at once.
●If 0 is set, if the chip size of MAX L and
MAX W exceeds ±1mm, it results in error
and no retry is carried out as usual.
0 0 to 100
Pickup position re-
teach count
This sets the maximum number of times
recognition is reattempted for a pickup
position recognition error.
00 to20
Splicing no-check stop
length [mm]
This is the stop length from the joint
detection position in splicing no-check.
●When 0 is set, the joint detection position
becomes the immediate stop position.
●When values other than 0 are set, it
becomes in the warning state and stops at
the length of the set value.
●This function is valid for the feeder
firmware version of 530 or later.
0 0 to 100
Parts empty judge
remains[%]
When the part empty pickup reaches to the
error count, if the number of remaining parts
is not below this set value, the machine
does not judge as parts empty. In this case,
pickup error is also counted.
0
0.000 to
99.999
Splicing judge remains
[%]
Even though splicing is detected, if the
remaining amount is not below this set value,
the machine does not judge as splicing.
●With 0 set, if splicing is detected, the
machine judges as splicing without any
condition.
0
0.000 to
99.999