NPM-TT2 EJM1EE-MB-05O-05
5-1-2-6
Setting information 5
System
administration
Type Item Description Initial
value
Setting
range
Timer
At time of
simultaneous transfer
requested singnal
delayed time[ms]
Sets the time to delay the simultaneous
transfer PCB request signal. This is used
when the PCB clamp timing is adjusted
such as cutout PCB.
0 0 to 20000
F Y clamp start delay
timer [ms]
This is used when the start timing of PCB Y
clamp on the F lane is adjusted.
This is available only when PCB Y clamp is
turned ON (option).
50 0 to 3000
F Y clamp forward
limit timer [ms]
This is used when the forward limit timing of
PCB Y clamp on the F lane is adjusted.
This is available only when PCB Y clamp is
turned ON (option).
50 0 to 3000
F Y clamp backward
limit timer [ms]
This is used when the backward limit timing
of PCB Y clamp on the F lane is adjusted.
This is available only when PCB Y clamp is
turned ON (option).
50 0 to 3000
R Y clamp start delay
timer [ms]
This is used when the start limit timing of
PCB Y clamp on the R lane is adjusted.
This is available only when PCB Y clamp is
turned ON (option).
50 0 to 3000
R Y clamp forward
limit timer [ms]
This is used when the forward limit timing of
PCB Y clamp on the R lane is adjusted.
This is available only when PCB Y clamp is
turned ON (option).
50 0 to 3000
R Y clamp backwa
This is used when the backward limit timing
of PCB Y clamp on the R lane is adjusted.
This is available only when PCB Y clamp is
turned ON (option).
50 0 to 3000
Wait for pre process
count Invalid time [s]
When the pre process wait time is shorter than
the setting time, it is not included in the pre
process count. (Counted in production time)
Normally, it is included in the pre process
count in such a case as when the loading
sensor being blocked from sensing the PCB
at the standby position for a brief time; so,
this can be used when you do not want to
take such a count.
00 to 10
Wait for post process
count Invalid time [s]
When the post process wait time is shorter
than the setting time, it is not included in the
pre process count. (Counted in production
time)
Normally, it is included in the post process
count in such a case as when the loading
sensor being blocked from sensing the PCB
at the standby position for a brief time; so,
this can be used when you do not want to
take such a count.
00 to 10
Conveyor(3/4)
NPM-TT2 EJM1EE-MB-05O-05
Unit
setting
Action parameter
setting 4
5-1-2-7
Setting information 6
Operating procedure
5-1-2
Type Item Description Initial
value
Setting
range
Mechanic
2mm Limit of the No2
origin offset(-)[mm]
The minus limit area of the second origin
offset on the 2mm feeder is set to narrower
when component supply condition is
degraded.
-1.0 -1.0 to 0.0
2mm Limit of the No2
origin offset(+)[mm]
The plus limit area of the second origin
offset on the 2mm feeder is set to narrower
when component supply condition is
degraded.
1.0 0.0 to 1.0
Feeder (1/6)
Type Item Description Initial
value
Setting
range
Timer
Motor OFF delay timer
while carrying out[ms]
Waiting time from when the sensor turns
OFF at the time of unloading a PCB till when
the transfer motor turns OFF.
0 0 to 10000
PCB over run waiting
time[s]
When returning after an overrun has been
detected, if the overrun sensor does not turn
OFF within this time, an error will result.
10 0 to 60
Determine
Palette pieces
between remote teach
runnings[Pieces]
Performs the remote teaching of the PCB
detect sensor (deceleration sensor unit) per
setting production volume.
0 0 to 100000
Pieces between support
pin checking
[Pieces/Lane]
(Lane1)
Rearrange the support pins when the
number of loaded PCBs reaches the setting
value.
(Lane 1)
The integrated value of the number of loaded
PCBs is reset to “0” at the time of replacing
or rearranging the support pins.
Enabled only for support pin auto change
specs.
0 0 to 100000
Pieces between support
pin checking
[Pieces/Lane]
(Lane2)
Rearrange the support pins when the
number of loaded PCBs reaches the setting
value.
(Lane 2)
The integrated value of the number of loaded
PCBs is reset to “0” at the time of replacing
or rearranging the support pins.
Enabled only for support pin auto change
specs.
0 0 to 100000
Position gap limit of
conveyor width[mm]
Checks the conveyor width before the start
of production, and adjust the conveyor width
if the measured value is larger than the
setting value.
0.5 0.0 to 1.5
Conveyor(4/4)
NPM-TT2 EJM1EE-MB-05O-05
5-1-2-8
Setting information 7
System
administration
Type Item Description Initial
value
Setting
range
Mechanic
4mm Limit of the No2
origin offset(-)[mm]
The minus limit area of the second origin
offset on the 4mm feeder is set to narrower
when component supply condition is
degraded.
-1.0 -1.0 to 0.0
4mm Limit of the No2
origin offset(+)[mm]
The plus limit area of the second origin
offset on the 4mm feeder is set to narrower
when component supply condition is
degraded.
1.0 0.0 to 1.0
Pickup position teach
count [cnt]
The recognition retry count if pocket
recognition error occurs
11 to9
Timer
BowlFeeder Vibration
time(Std)[ms]
Bowl Feeder vibration time (Std) 250 0 to 30000
BowlFeeder Vibration
time(Mid)[ms]
Bowl Feeder vibration time (Mid) 500 0 to 30000
BowlFeeder Vibration
time(Slow)[ms]
Bowl Feeder vibration time (Slow) 1000 0 to 30000
Verification2 limit time
of pulling out and
inserting[s]
With “Verification 2” turned ON and set to
any value other than “0”, a feeder is not
required to be verified again if you pull out
or insert the feeder within the setting time
frame.
Re-verification is required when the value
is “0”.
00 to60
Determine
Bad feeder error
rate [%]
This is a criterion used to judge whether
feeders are good or bad.
The feeder whose error rate exceeds the
set value is considered a bad feeder, and
the machine stops on error.
20 0.1 to 100
Parts empty pickup
error times (8 mm)
[piece]
If the set number of pickup errors occurs
successively in the 8 mm wide reel, the
machine
judges it as a shortage.
15 3 to 30
Parts empty pickup
error times (over 12
mm) [piece]
If the set number of pickup errors occurs
successively in the 12-mm-or-more wide
reel,
the machine judges it as a shortage.
33 to 30