NPM-TT2 EJM1EE-MB-04O-03
4-2-9-10
Produc-
tion data
teaching
Placement coordinates
teach 6
Operating procedure
4-2-9
7
Align the cross line to the top of the component
electrode.
Align the cross line to an
electrode on the PCB
The edge face of the component to align the
cross line differs depending on regular
component mount angle. (See below)
8
Align the cross line to the right of the
component electrode.
The edge face of the component to align the
cross line differs depending on regular
component mount angle. (See below)
Angle
0° 90° 180° -90°
Position
Measure 1
Measure 3
Measure 2
Measure 4
Electrode position on a PCB align the cross line
+
8
7
are selected
are selected
When and
When and
Teaching with component (measuring method: 2 point) 2
Notice1 (→P.4-2-9-6)
+
+
NPM-TT2 EJM1EE-MB-04O-03
4-2-9-11
Setting
change
Type Action
Return to the screen in of
[Teaching with component
(measuring method: 1 point)]
Repeat once steps from to
2 8
9
Perform steps from to ,
changing from [Top] to [Bottom].
5
7
Perform steps from to ,
changing from [Right] to [Left].
5 7
The edge face of the component to align the cross
line differs depending on mount angle. (See below)
10
Press any of the following buttons
1
5
2
Return to the screen in
Return to the screen in of
[Teaching with component
(measuring method: 1 point)]
10
are selected
are selected
When and
When and
90° 180° -90°
Measure 1
Measure 3
Measure 2
Measure 4
The edge face position to align the cross line
Angle
Position
NPM-TT2 EJM1EE-MB-04O-03
4-2-9-12
Produc-
tion data
teaching
Placement coordinates
teach 7
Operating procedure
4-2-9
11
12
11
Confirm the message
When you do not save the teach
result
12
Confirm the message
When you do not calibrate the
angle
Teaching with component (measuring method: 2 point) 3
13
13
Confirm the message
When you do not save the data