N7201A652E.pdf - 第48页
NPM- TT2 EJM1EE-SF-01N-05 1-4 -1 Pr ecautions 1 1-4 Precautions in use ● Do not move noise sources such as welders close to equip ment. A malfunction may occur. ● During the ope ration of equipment, avoid turning OFF the…

NPM-TT2 EJM1EE-SF-01N-05
1-3-3-2
NOTICE
●Be sure to connect the device or the conveyor satisfied the machine safety requirements such as
ISO13849-1 or IEC6201.
●Keep the safety distance of 600 mm or more from the opening in order not to reach hands into the
opening of the NPM-TT2 from the adjacent device or conveyor. (Reference (1))
●If you can keep only the safety distance of 400 to 600 mm from the opening of the NPM-TT2, install the
safety sensor on the PCB transfer opening, and output the safety support signal to the NPM-TT2.
(Reference (2))
●Take measures not to insert hands or fingers from the space between the NPM-TT2 and the device or
the conveyor.
●Install the full cover that usually you cannot open or close, to the transfer rail of the device or the
conveyor.
If you can reach the PCB transfer opening with the open/close cover installed, install the safety switch,
and output the safety support signal to the NPM-TT2 while the cover is open. When the cover is open,
the NPM-TT2 stops for confirming safety.(Reference (3))
●About detailed conditions regarding machine safety or safety about connection with machines
manufactured by us (CM series), please ask us.
PCB transfer opening
PCB transfer opening
Peripheral
equipment
(conveyor)
Peripheral equipment
(placement machine)
(1) 600 mm or more
(2) If the space is only 400 mm to
600 mm, the transfer opening
sensor is necessary
(1) 600 mm or more
(2) If the space is only 400 mm to
600 mm, the transfer opening
sensor is necessary
(3) Full cover
●Safety switch is
required for the
open/close cover
Confirmation

NPM-TT2 EJM1EE-SF-01N-05
1-4-1
Precautions 1
1-4
Precautions in use
●Do not move noise sources such as welders close to equipment. A malfunction may occur.
●During the operation of equipment, avoid turning OFF the power switch of the main controller, the servo
switch and the air unnecessarily.
Because equipment operates independently without being controlled, breakage may occur.
●During instruction or when moving a unit with the servo free from stress, be sure that there is no
interference. Breakage may occur.
●The tray feeder cover is locked with a cylinder. Forcing open the cover may cause breakage of the cover
or the cylinder.
●Do not take apart or alter the main body of equipment or the unit. It may affect the level of safety and
quality control of products.
●Data should only be changed by authorized personnel, who have received special training.
A malfunction may occur due to improper input.
●Do not block the fan outlet and inlet. Abnormal action arising from the increase in temperature inside the
control box may occur.
●Do not turn OFF the servo switch during operation. It may cause machine to malfunction. Turn it OFF
when the machine is in a temporary stop state (single stop or cycle stop) or operation stop state.
●Pay attention to water quality when using a spray or humidifier. In humidifiers, ultrasonic humidifiers in
particular, depending on the water quality though, not only calcium and magnesium (as the primary
components of water hardness) but also silica, carbonate, iron, and others are released into the air in form
of floating dust and gradually deposited on the machine in form of dust, which causes the sliding part or
optical system of the machine to malfunction.
●Do not use in an atmosphere where low molecular siloxones released from silicon-based materials
(silicone adhesive, silicon oil or powder, etc.) in gaseous form are present. Depositing of low molecular
siloxane on the electric contact or optical part of the machine causes a contact fault or malfunction.
●We have no responsibility regarding the followings.
・ Improper usage, and trouble and damage due to inappropriate repair or remodel
・ Accidental damage arising from the machine use or fail such as loss of business interests, or change
or deletion of memory data
・ Trouble or damage caused by relocation, transportation or drop of the machine after purchased
・ Trouble or damage caused by fire, an earthquake, flood damage, lighting strike or any other act of
providence, and environmental pollution, salt pollution, gas pollution (corrosive gas, halogen gas, etc.),
abnormal voltage and power supplies, other than specified (voltage, frequency)
・ Trouble and damage arising when transported by vehicles and ships
・ Damage arisen from not being observed described matters in the manuals included in this product
Precautions for Maintenance and Inspection
■Follow the instruction manual when engaged in maintenance or inspection.
●Refer to the Operating procedure and the Maintenance, which come with equipment, for maintenance and
inspection.
●Turn OFF the main power switch and the pneumatic source (cock) before maintenance or inspection.
Locking is recommended to ensure your safety.
●When cleaning parts of the equipment not mentioned in the instruction manual, wipe with a soft dry cloth.
For dirty spots, dampen a cloth with a neutral detergent diluted with water, and wipe the spots after
wringing out the wet cloth.
After cleaning with the damp cloth, dry with a dry cloth.
●When cleaning inside the clean room, use cleaning implements provided for the clean room.
●Do not use an organic solvent or the like because it contributes to the following.
・Cracking or deterioration of plastic parts
・Rapid decline in antistatic effect

NPM-TT2 EJM1EE-SF-01N-05
1-4-2
Confirmation
■Clean the area around equipment when the equipment is not in use.
When cleaning equipment, be sure to turn the power source off and do
not use an air gun.
●The unit and products may be exposed to dust, thereby causing adverse influence on equipment and
products.
・ Never use combustible solvent. It causes smoking and an ignition by catching fire.
・ Never use acetone and methanol (methyl alcohol). It causes machine malfunction.
・ Do not use ethanol (ethyl alcohol), IPA (isopropyl alcohol) or mixed solvent of ethanol with IPA. (It does not
conform to CE)
・ Use new cleaning solvent. Never reuse solvent.
■To ensure safety, please use [water-soluble solvent ] for cleaning
solvent.
Security precautions
●Machine password is not set as default. Please set a password after the machine is delivered to you.
●After performing operation that password entry is required, change the mode to the normal mode
(Operator mode.)
●Connect the machine, LNB and NPM-DGS to intranet before use.
●Keep your password safe and should not disclose it to any other person.
●When you send or dispose of the computer used for the LNB or NPM-DGS, remove the hard disk or
initialize it.
●When an SD card is used in emergency operation such as network error, delete the data in the SD card
after returning to normal operation.
●Recorded information on the SD card may not be completely deleted by the basic function of the
operation system. We recommend to use commercial software that can delete the data completely.
●When you transfer or dispose of the SD card, erase all data on the SD card.
●If you do not follow above precautions, you may crack a user ID, your password or your production
data by the third parity with knowledge.
Precautions in working near linear motors
■Keep iron or other magnetic bodies (e.g. tools, jigs, and bolts),
watches, cellular phones, and magnetic cards at least 40 mm away
from the linear motors.
●The linear motor incorporates strong magnets. The metallic objects (magnetic bodies) you are holding
may be attracted or your fingers may get pinched between the objects and magnet.
●Depending on shapes of magnetic bodies, they may not be able to be detached from each
other. Small parts can be removed by hand. (There is no problem if you touch the permanent
magnets with bare hands.)
●Due to extremely powerful magnetic force, watches and cellular phones may be broken and data of
magnetic cards may be corrupted.
●See “1-1 Safety precautions 3” for details.