6 At a Glance

NPM-TT2 EJM1EE-MB-05O-05
5-3-13-2

6 At a Glance

NPM-TT2 EJM1EE-MB-06O-04
Specifi-
cation
Machine specifications/
Basic performance 1
Machine specifications
Item
Specification
Control system Microcomputer system
External memory
The data is managed by LNB
*3)
Approximately 1MB is required for a piece of data
Program data
*1)
Placement points Maximum 10 000 points per machine
(Including placement coordinates, recognition mark
coordinates, bad mark coordinates and PCB warpage
measurement points)
* When PCBs are produced in dual lane mode, placement
points shall be the total of front and rear lanes. When
placement points exceed 10 000 points, please consult us.
When your machine line is mixed line with the CM/DT series,
please consult us.
Power
source
Machine body
Normal service power source: Three-phase AC 200 / 220
±10 V, Three-phase AC 380 / 400 / 420 / 480 ±20 V
Frequency: 50 /60 Hz
Peak current value during operation: 40 A (rated voltage AC
200 V)
Rated
capacity
Machine body 2.5 kVA
Supply air pressure 0.5 to 0.8 MPa (working air pressure: 0.500 to 0.505 MPa)
Supply air volume 200 L / min (A.N.R.)
Outside
dimensions
Main body only
W 1 300 D 2 628 H 1 444 mm
(The signal tower and the touchscreen are not included)
With a supply unit
■When a tray feeder
*4)
is connected
W 1 300 D 2 798 H 1 444 mm
(The signal tower and the touchscreen are not included)
■When feeder carts
*4)
are coupled to both the front and rear
sides
W 1 300 D 2 893 H 1 444 mm
(The signal tower and the touchscreen are not included)
Mass
*2)
Main body
2 690 kg per unit (Mass of 200kg per unit of a standard
configuration single tray feeder
*4)
is not included)
Single tray feeder
*4)
200 kg per unit
Feeder cart
*4)
110 kg per unit
Standard configuration
3 090 kg (one main unit and two single tray feeders
*4)
)
Environmental condition
Temperature: 10 to 35C
Humidity: 25 to 75% RH (no condensation)
Transportation and storage condition
Temperature: -20 to 60C
Humidity: 75% RH or less (no condensation)
Altitude 1 000 m or less above sea level
Noise < 70 dB (A)
6-1-1-1
Operating procedure
6-1-1
1)
This machine can modify only some data. The data is created by NPM-DGS.
NPM-DGS is software creating production data for NPM (not included in this product)
2)
Mass of the main body excluding the optional units.
3)
LNB (Line network box) manages the production data shared in the line.
4)