N7201A652E.pdf - 第393页

NPM- TT2 EJM1E E-MB-05O-05 5-1-1 -16 System administration Setting information 15 No. Item name Function w hen [ON] is selec ted 1 Production report clear at auto product change Clear s the p roduction re port at produc …

100%1 / 512
NPM-TT2 EJM1EE-MB-05O-05
5-1-1-15
Setting information 14
Unit
setting
Option setting 8
Operating procedure
5-1-1
No. Item name Function when [ON] is selected
1
Measure by the
height sensor (front)
Measures the board height (warp) by the height sensor, in order to control the
nozzle height during mounting.
2
Measure by the
height sensor (rear)
Measures the board height (warp) by the height sensor, in order to control the
nozzle height during mounting.
Default OFF
Height sensor
No. Item name Function when [ON] is selected
1
Over judge input
again
When inspection by the inspection head has resulted in NG, this option
allows judgment (OK/NG) for the NG component to be input again on the
Over judge screen.
Default OFF
Inspection head
NPM-TT2 EJM1EE-MB-05O-05
5-1-1-16
System
administration
Setting information 15
No. Item name Function when [ON] is selected
1
Production report
clear at auto product
change
Clears the production report at production changeover.
2
Production report
clear at the other lot
name auto product
change
Clears the production report only when changing production to a different lot
name.
The report is cleared also when the MJS ID differs.
3
Display transfer
direction of status
monitor PCB
Displays the PCB flow direction on the Status monitor screen.
4
Buzzer stop button
auto change
Changes the function button to [Buzzer stop] automatically when the buzzer
sounds.
5 PCB warp correction
Estimates the board warp based on the heights measured by sensor at
several points on the board, in order to control the mounting height.
6
Pre-pickup inspection
at run resume
Executes pre-pickup check if suspended automatic operation is restarted on
the Production start screen
No. Item name Function when [ON] is selected
1
Time-lapse change
calibration
Performs calibration for time-lapse change.
No. Item name Function when [ON] is selected
1
Vacuum sensor error
detection
Detects error by the vacuum sensor during automatic operation.
2
Nozzle holder filter
detect during head
maintenance
Detects the presence of nozzle holders when the head maintenance unit is
used.
Default ON
Whole (suspension)
Default ON
XY unit (suspension)
Default ON
Head (suspension)
NPM-TT2 EJM1EE-MB-05O-05
5-1-1-17
Setting information 16
Unit
setting
Option setting 9
Operating procedure
5-1-1
No. Item name Function when [ON] is selected
1 PCB in when stop
Prohibits the loading of next PCB from the upstream process during single
stop or cycle stop.
2 PCB out when stop
Carries out the PCB waiting in the machine to the downstream process
during single stop or cycle stop.
3 Wait between MC
Determines whether or not to have a PCB held in between the machines in
the line where the NPM is directly connected upstream or downstream the
machine.
4 Simultaneous transfer Enables PCB unloading and loading of the next PCB at the same time.
5
Support action time
being shortened
Lowers the support to the “both sides mount height”, and raises it after the
next PCB is loaded.
6
Keep clamping in
cycle stop
Keeps the clamp engaged during cycle stop.
7 Pre carry out
Unloads PCBs, to which post waiting is not available, into a place as far away
as possible upon completion of placement.
No. Item name Function when [ON] is selected
1
Cover tape error
detected
Detects cover tape (cover tape) exhaust and tape jamming error.
2
Tape joint error
detect
Detects tape joint error.
3
Component remains
input
Allows the part remainder to be input manually after splicing.
4
Syringe trans material
empty stop
Causes the machine a single stop if material empty has been detected by
the sensor during automatic operation.
5
Tape feed during the
production
Feeds the tape during production.
6
Return to origin after
pickup pos teach
Performs origin return after pickup position teaching. When OFF is selected,
one part will be fed after pickup position teaching.
Default ON
Conveyor (suspension)
Default ON
Feeder (suspension)