N7201A652E.pdf - 第395页

NPM- TT2 EJM1E E-MB-05O-05 5-1-1 -18 System administration Setting information 17 No. Item name Function w hen [ON] is selec ted 7 Substituted parts list Data switch When comp onent has been sw itched from master to s ub…

100%1 / 512
NPM-TT2 EJM1EE-MB-05O-05
5-1-1-17
Setting information 16
Unit
setting
Option setting 9
Operating procedure
5-1-1
No. Item name Function when [ON] is selected
1 PCB in when stop
Prohibits the loading of next PCB from the upstream process during single
stop or cycle stop.
2 PCB out when stop
Carries out the PCB waiting in the machine to the downstream process
during single stop or cycle stop.
3 Wait between MC
Determines whether or not to have a PCB held in between the machines in
the line where the NPM is directly connected upstream or downstream the
machine.
4 Simultaneous transfer Enables PCB unloading and loading of the next PCB at the same time.
5
Support action time
being shortened
Lowers the support to the “both sides mount height”, and raises it after the
next PCB is loaded.
6
Keep clamping in
cycle stop
Keeps the clamp engaged during cycle stop.
7 Pre carry out
Unloads PCBs, to which post waiting is not available, into a place as far away
as possible upon completion of placement.
No. Item name Function when [ON] is selected
1
Cover tape error
detected
Detects cover tape (cover tape) exhaust and tape jamming error.
2
Tape joint error
detect
Detects tape joint error.
3
Component remains
input
Allows the part remainder to be input manually after splicing.
4
Syringe trans material
empty stop
Causes the machine a single stop if material empty has been detected by
the sensor during automatic operation.
5
Tape feed during the
production
Feeds the tape during production.
6
Return to origin after
pickup pos teach
Performs origin return after pickup position teaching. When OFF is selected,
one part will be fed after pickup position teaching.
Default ON
Conveyor (suspension)
Default ON
Feeder (suspension)
NPM-TT2 EJM1EE-MB-05O-05
5-1-1-18
System
administration
Setting information 17
No. Item name Function when [ON] is selected
7
Substituted parts list
Data switch
When component has been switched from master to substitute, this option
switches the parts data from master to substitute accordingly.
8 Tape guide check
When an auto load feeder is used for production, the machine checks whether
the tape guide is properly attached at the start of production or at the time of
removal or insertion of the feeder during production.
9
Insert entrance shutter
link
When auto load feeders are used for production, the reel inlet shutter is
opened only if part has been verified.
10 NG Feeder Detect
Shows an error indicating unavailable for the feeders that were judged as NG
by the feeder maintenance unit. No error is shown when set to OFF.
11 Unverified feeder alert
Shows the message “Unverified feeder” for the feeders that are used in
production but have no part name in the feeder memory.
12
Stackable stick feeder
parts verify
Makes the stack stick feeders subject to parts collation. When “Feeder parts
collation” is switched from OFF to ON, this option will also be switched to ON.
Default ON
Feeder (suspension)
No. Item name Function when [ON] is selected
1 Use tray supply side
Allows tray parts to be replenished and NG pallet parts to be removed from
the tray supply side during production.
2
Prod unused parts
supply action
Prevents the pallets not used for production from moving to the tray supply
side even when parts are exhausted.
3
Tray pre supply of
exceeding priority
Supplies pallets during inspection and prepares for the next mounting
preferentially when the inspection head and mount head have been set on
the machine and the order of their tasks has been fixed.
Default ON
Tray (Suspension)
NPM-TT2 EJM1EE-MB-05O-05
Unit
setting
Action parameter
setting 1
5-1-2-1
You can set the parameters for system actions.
1
2
A
B
Operating procedure
5-1-2
Choose the type of action parameter
To set the size
To set the timer
To determine
Setting status of action
parameter
The previous or next table is
displayed.
Edit data on the screen as
needed
Touching the screen opens the input
window.
To set as standard specifications
(Initialize)
B
11 2
A