N7201A652E.pdf - 第458页
NPM- TT2 EJM1E E-MB-05O-05 5-3-4 Machine parame- ter Head origin of fset ch e ck You can check the origin offset values (calibration result) of θ -/Z-axes. A B B A Operating procedure 5-3-4 θ [ ° ] Offset angle on head o…

NPM-TT2 EJM1EE-MB-05O-05
31
1
3
5-3-3-2
■To change the offset display area using a matrix
2
4
5
B
3
2
5
Touch the display area
(Matrix moves right or left)
(Offset of the area selected in is
displayed in )
■When you do not select the area to
display the offset
Choose an area to display the
offset
■When you do not clear plane
correction parameters
Confirm the message
System
administration

NPM-TT2 EJM1EE-MB-05O-05
5-3-4
Machine
parame-
ter
Head origin offset
check
You can check the origin offset values (calibration result) of θ-/Z-axes.
A
B
B
A
Operating procedure
5-3-4
θ [°]
Offset angle on head origin.
Z [mm]
Offset of the height direction of Z-axis
of each placement head.

NPM-TT2 EJM1EE-MB-05O-05
You can check rotation center offset (calibration result) of each nozzle head.
5-3-5
Machine
parame-
ter
Head rotation center
check
Operating procedure
5-3-5
System
administration
B
A
F
C
D
E
Switches the display of [Rotate center]
to the value used in recognizing
components with the line camera.
Rotate center X[mm]/Y[mm]
XY coordinates of rotation center.
Switches to the value being temporarily
retained after measurement.
Standard value of rotation center that is
used in correcting temporal changes.
Switches the display of [Rotate center] to
the value used in mounting the 3D
sensor.
Amount of change in the reference
rotation center that occurs during
temporal change correction.
A B C
E FD