Dek-265GSX-User-Manual.pdf.pdf - 第121页
Parameter Definition Image Y Justification This parameter defines the position of the image about the Image Y parameter. The image can be front, rear or centre justified about Image Y. Options are: Front; Rear; Centre. D…

Parameter Definition
Image Detail This parameter allows the user to modify the screen image data of the
selected screen library file. Once selected, pressing Incr. or Decr. Keys opens
the Image Detail Configuration page.
NOTE
This parameter is only displayed, if Screen Size in Set Preferences has been
selected to Screen Library.
Mesh Front This parameter sets the distance between the inner edge of the screen frame
and the screen glue line at the front of the frame. It defines the area that
should not be contacted by the squeegees/ProFlow.
Minimum 0mm
Maximum Screen Length - 250mm
Increment 0.1mm
Default 38mm
Mesh Rear This parameter sets the distance between the inner edge of the screen frame
and the screen glue line at the rear of the frame. It defines the area that
should not be contacted by the squeegees/ProFlow.
Minimum 0mm
Maximum Screen Length - 250mm
Increment 0.1mm
Default 38mm
Mesh Left This parameter sets the distance between the inner edge of the screen frame
and the screen glue line at the left of the frame. It defines the area that should
not be contacted by the squeegees/ProFlow.
Mimimum 0mm
Maximum Screen Width - 250mm
Increment 0.1mm
Default 38mm
Mesh Right This parameter sets the distance between the inner edge of the screen frame
and the screen glue line at the right of the frame. It defines the area that
should not be contacted by the squeegees/ProFlow.
Minimum 0mm
Maximum Screen Width - 250mm
Increment 0.1mm
Default 38mm
Image X This parameter defines the dimension in the X axis from the right inner edge
of the screen frame to either:
Right hand edge of the image - right justified image
Left hand edge of the image - left justified image
Centre line of the image - centre justified image
Minimum 60mm
Maximum Screen Width - 100mm
Increment 0.1mm
Default 330.4mm
Image Y This parameter defines the dimension in the Y axis from the front inner edge
of the screen frame to either:
Front edge of the image - front justified image
Rear edge of the image - rear justified image
Centre line of the image - centre justified image.
Minimum 60mm
Maximum Screen Width - 100mm
Increment 0.1mm
Default 330.4mm
Image X Justification This parameter defines the position of the image about the Image X
parameter. The image can be left, right or centre justified about Image X.
Options are:
Left; Right; Centre.
Default Centre
1.104 User Manual Software Version 6
MACHINE PROGRAMMING
MENU PARAMETERS

Parameter Definition
Image Y Justification This parameter defines the position of the image about the Image Y
parameter. The image can be front, rear or centre justified about Image Y.
Options are:
Front; Rear; Centre.
Default Centre
Barcode Y This parameter defines the dimension between the centre of the barcode to the
outer rear edge of the screen frame or adaptor.
Minimum 10mm
Maximum Screen Length - 10mm
Increment 0.1mm
Default 97mm
Front Knead Speed This parameter sets the speed of kneading in the forward direction
Minimum 2mm/sec
Maximum 150mm/sec
Increment 1mm/sec
Default 10mm/sec
Rear Knead Speed This parameter sets the speed of kneading in the rearward direction.
Minimum 2mm/sec
Maximum 150mm/sec
Increment 1mm/sec
Default 10mm/sec
Front Knead Pressure This parameter sets the pressure to be applied, while using squeegees, when
kneading in the forward direction.
Minimum 0kg
Maximum 20kg
Increment 0.2kg
Default 5kg
Rear Knead Pressure This parameter sets the pressure to be applied, while using squeegees, when
kneading in the rearward direction.
Minimum 0kg
Maximum 20kg
Increment 0.2kg
Default 5kg
ProFlow Knead Pressure This parameter sets the pressure to be applied, while using ProFlow, when
kneading in either direction.
Minimum 0kg
Maximum 20kg
Increment 0.2kg
Default 10kg
Paste Recovery Rate This parameter sets the frequency, measured in print strokes completed in
either direction, at which paste roll recovery occurs in both directions, when
using squeegees.
Minimum 0 (This disables paste roll recovery)
Maximum 500
Increment 1
Default 1
Front Paste Recovery This parameter sets the extent of paste roll recovery movement while
begining the rearward print stroke. The movement is measured forward from
the print stroke start position.
Minimum 0mm
Maximum 15mm (Subject to the front turnaround
envelope)
Increment 1mm
Default 5mm
Software Version 6 User Manual 1.105
MACHINE PROGRAMMING
MENU PARAMETERS

Parameter Definition
Rear Paste Recovery This parameter sets the extent of paste rol recovery movement while begining
the forward print stroke. The movement is measured rearward from the print
stroke start position.
Minimum 0mm
Maximum 15mm (Subject to the rear turnaround
envelope)
Increment 1mm
Default 5mm
Tooling Deviation This parameter sets the extent of tooling deviation before a warning message
is posted.
Minimum 0%
Maximum 50%
Increment 0.25%
Default 20%
1.106 User Manual Software Version 6
MACHINE PROGRAMMING
MENU PARAMETERS