Dek-265GSX-User-Manual.pdf.pdf - 第122页

Parameter Definition Rear Paste Recovery This parameter sets the extent of paste rol recovery movement while begining the forward print stroke. The movement is measured rearward from the print stroke start position. Mini…

100%1 / 388
Parameter Definition
Image Y Justification This parameter defines the position of the image about the Image Y
parameter. The image can be front, rear or centre justified about Image Y.
Options are:
Front; Rear; Centre.
Default Centre
Barcode Y This parameter defines the dimension between the centre of the barcode to the
outer rear edge of the screen frame or adaptor.
Minimum 10mm
Maximum Screen Length - 10mm
Increment 0.1mm
Default 97mm
Front Knead Speed This parameter sets the speed of kneading in the forward direction
Minimum 2mm/sec
Maximum 150mm/sec
Increment 1mm/sec
Default 10mm/sec
Rear Knead Speed This parameter sets the speed of kneading in the rearward direction.
Minimum 2mm/sec
Maximum 150mm/sec
Increment 1mm/sec
Default 10mm/sec
Front Knead Pressure This parameter sets the pressure to be applied, while using squeegees, when
kneading in the forward direction.
Minimum 0kg
Maximum 20kg
Increment 0.2kg
Default 5kg
Rear Knead Pressure This parameter sets the pressure to be applied, while using squeegees, when
kneading in the rearward direction.
Minimum 0kg
Maximum 20kg
Increment 0.2kg
Default 5kg
ProFlow Knead Pressure This parameter sets the pressure to be applied, while using ProFlow, when
kneading in either direction.
Minimum 0kg
Maximum 20kg
Increment 0.2kg
Default 10kg
Paste Recovery Rate This parameter sets the frequency, measured in print strokes completed in
either direction, at which paste roll recovery occurs in both directions, when
using squeegees.
Minimum 0 (This disables paste roll recovery)
Maximum 500
Increment 1
Default 1
Front Paste Recovery This parameter sets the extent of paste roll recovery movement while
begining the rearward print stroke. The movement is measured forward from
the print stroke start position.
Minimum 0mm
Maximum 15mm (Subject to the front turnaround
envelope)
Increment 1mm
Default 5mm
Software Version 6 User Manual 1.105
MACHINE PROGRAMMING
MENU PARAMETERS
Parameter Definition
Rear Paste Recovery This parameter sets the extent of paste rol recovery movement while begining
the forward print stroke. The movement is measured rearward from the print
stroke start position.
Minimum 0mm
Maximum 15mm (Subject to the rear turnaround
envelope)
Increment 1mm
Default 5mm
Tooling Deviation This parameter sets the extent of tooling deviation before a warning message
is posted.
Minimum 0%
Maximum 50%
Increment 0.25%
Default 20%
1.106 User Manual Software Version 6
MACHINE PROGRAMMING
MENU PARAMETERS
SPC CONFIGURATION
Whenthe cursor on the EditCurrent Process Parameterspage highlightsthe SPC
Configuration option and Incr. or Decr. are pressed an SPC Configuration
Window opens and two extra menu options become available:
Configuration
Window
Theconfiguration window allows the user to setup the MachinesSPCoperation.
Data Output Rate Two rates of data output are available as follows:
Every Cycle - Outputs SPC data every cycle except for the camera data, which is
output dependant upon the settings of the parameters start rate, sample rate and
start rate limit.
On Inspect - Outputs all SPC data at a rate dependant upon the settings of the
parameters start rate, sample rate and start rate limit.
Start Rate Sets the initial SPC output rate, for setting up a line. If start rate is set to 10, SPC
data is output every 10 cycles until the start rate limit is reached, when the rate
becomes that set in the sample rate parameter. The range is 1-100.
Sample Rate Sets the rate of SPC output after the start rate limit has been reached. The range
is 0-100, where 0 = use start rate until start rate limit is reached. If sample rate is
setto 15, SPC data is output every 15cyclesafterthestartrate limit is reached.
Start Rate Limit Sets the amount of SPC output cycles at the start rate. When this limit is reached
the sample rate parameter becomes the active SPC output rate. The range is
0-100, where 0 = continuous SPC output at the start rate.
NOTE
Setting both start rate limit and sample rate to zero causes continuous SPC
output at the start rate.
Software Version 6 User Manual 1.107
MACHINE PROGRAMMING
SPC CONFIGURATION
SPC Configuration Page.
DATA OUTPUT RATE
START RATE
SAMPLE RATE
START RATE LIMIT
SPC DATA MODE
SPC FORMAT
UPDATE ON START-UP
ALIGN INSPECT MODE
EVERY CYCLE
1
10
10
SERIAL
WINDOWS
NO
PRE PRINT
cycles
cycles
cycles