PRINT HEAD The Print Head Diagnostic module contains the following: Raise Head Under 2 Button Control Lower Head Under 2 Button Control Toggle Head Latch on/off Toggle Lid Bolt on/off Head Up Sensor on/off Head Down Sens…

Analogue Input
Status
Selecting this option displays a window showing the analogue output of the load
cell amplifier card of the squeegee pressure mechanism.
Analogue Input Values
Tri-colour Beacon Selecting any one of the three colours toggles them between on and off.
Data Logging Selecting this function alternately enables and disables data logging during
diagnostic operation.
Change Edit
Password
Selection of this option prompts the operator to enter a new password.
Change Diagnostic
Password
Selecting this option either allows a password to be inputted or changes an
existing password. This password protection inhibits unauthorized entry into
diagnostics.
Change DOS
Password
Selecting this option either allows a password to be inputted or changes an
existingpassword. Thispassword protection inhibits unauthorized exit to DOS.
Change Adjust
Password
Selecting this option allows a password to be inputted or changes an existing
password. This password protection inhibits unauthorized adjustments.
Change Fiducial
Set Up Pasword
Selecting this option allows a password to be inputted or changes an existing
password. This password protectioninhibits unauthorized entry into the fiducial
set up.
Change Network
Auto-login
Password
Selecting this option allows a password to be inputted or changes an existing
password. This password protection inhibits unauthorised access to the
network.
Terminate Control
and Return to DOS
Selecting this option terminates the machine and returns to the DOS prompt.
Software Version 6 User Manual 5.13
DIAGNOSTICS
SYSTEM

PRINT HEAD The Print Head Diagnostic module contains the following:
Raise Head Under 2 Button Control
Lower Head Under 2 Button Control
Toggle Head Latch on/off
Toggle Lid Bolt on/off
Head Up Sensor on/off
Head Down Sensor on/off
Lid Bolt Shut on/off
Head Prop Stowed on/off
Left Jog Button on/off
Right Jog Button on/off
The menu bar changes to the following:
RunDiagnost activates the diagnostic function, as selected by thehighlightbar.
Next/Previous keys move the highlight bar up and down the list of selectable
diagnostic functions.
Exit returns operation to the module diagnostics page.
Raise Head Under
2 Button Control
Selecting this option allows the print head to be raised using the two button
safety switches located on the front of the machine. These switches must be
operated simultaneously.
Lower Head Under
2 Button Control
Selecting this option allows the print head to be lowered using the two button
safety switches located on the front of the machine. These switches must be
operated simultaneously.
Toggle Head Latch Selecting this option alternately switches the print head magnetic latches on and
off.
Toggle Lid Bolt Selecting this option alternately switches the printhead shot bolt on and off.
Head Up Sensor This option displays the head up sensor status.
Head Down Sensor This option displays the head down sensor status.
5.14 User Manual Software Version 6
DIAGNOSTICS
PRINT HEAD

Lid Bolt Shut This option displays the operation of the printhead shot bolt located on the front
of the machine.
Head Prop Stowed This option displays the pit prop stowed status.
Left Jog Button This option displays the operation of the left button of the two button safety
switches located on the front of the machine.
Right Jog Button This option displays the operation of the right button of the two button safety
switches located on the front of the machine.
Software Version 6 User Manual 5.15
DIAGNOSTICS
PRINT HEAD