Dek-265GSX-User-Manual.pdf.pdf - 第192页

Error Message Intrepretation X Actuator Limit Exceeded This error reports that either X actuators are driven past its limit set during calibration. Y Actuator Limit Exceeded This error reports that either Y actuators are…

100%1 / 388
Error Message Intrepretation
Screen Cleaner Out Of Position This error reports that the screen cleaner is out of position.
Possible causes are:
Screen Cleaner not at the home position.
Home sensor - enter diagnostics, digital inputs and check the
sensor changes state.
If a screen cleaner is not fitted , check that the home sensor is not
connected.
Screen Couplings Not Extended This error reports that the screen couplings have failed to extend
within the 4 second time-out period.
Screen Fiducial Not Found This error reports that the vision system has been unable to locate
the screen fiducial.
Screen Not Correctly Located.
Reposition !
( Lt machines only)
This error reports that a screen has not been detected by the screen
at rear sensor.
Screen XF Error This error reports that the X forward screen actuator failed to
initialize to its central datum.
Screen XR Error This error reports that the X rear screen actuator failed to initialize
to its central datum.
Screen Y Error This error reports that the Y screen actuator failed to initialize to
its central datum.
Set Pressure %2.21f Actual
Pressure %2.21f
(Front/Rear Squeegee)
This error reports if the front/rear squeegee pressure differs from
the pressure set by more than ± 1.00Kg.
Stop After Idle Time Exceeded This error reports if the idle time is exceeded, the options to
continue or abort are displayed. Continue resets the idle timer or
abort allows for Manual or Auto unload.
System Power Down This error reports that the 24V motor power has been switched off
either by the Emergency Stop button being activated (including
upline and downline external machines) or that the removable
frame access cover has been removed
System Suspended While Covers
Open
This error reports that whilst the machine was switched on, one or
more of the cover interlock switches were out of position.
Table Movement Inhibited,
Camera Not Home.
This error reports that the camera is over the table and the mint is
sent an instruction to move the rising table.
This Diagnostic Cannot Run Until
Proflow Is At home
This error reports if proflow is not in the home position (Print
Carriage Diagnostics only).
This Diagnostic Cannot Run With
Proflow Fitted
This error reports if in Print Carriage Diagnostics, Move Print
Carriage to Paste Position is selected.
Unable to Find Fiducial This error reports that the vision system is unable to locate the
relevant screen or board fiducial.
Upline Board Transfer Error This indicates that there is a problem in loading a board from the
upline machine.
Upline Machine Not Available This error reports that the upline machine is unavailable to accept
the next board.
Window Error This error reports that the menu structure has failed to open
correctly.
Software Version 6 User Manual 4.7
ERROR MESSAGES
ERROR MESSAGE LISTING
Error Message Intrepretation
X Actuator Limit Exceeded This error reports that either X actuators are driven past its limit set
during calibration.
Y Actuator Limit Exceeded This error reports that either Y actuators are driven past its limit set
during calibration.
4.8 User Manual Software Version 6
ERROR MESSAGES
ERROR MESSAGE LISTING
CHAPTER 5
DIAGNOSTICS