Dek-265GSX-User-Manual.pdf.pdf - 第307页
Parameter Definition Site Y Coord The coordinate of a site taken from the front left corner of the board, in the Y direction. Minimum - 0.0mm Maximum - Board Width Increments - 0.1mm Default - 59.5mm Site Width The width…

Parameter Definition
Low Paste Action This parameter sets the action performed on a low paste alarm. The
options are:
Manual
Re-print
Default - Manual
Inspect After Clean This parameter sets whether a screen is inspected before the next board is
printed following a screen clean. The options are:
Disabled
Enabled
Default - Disabled
Post Print Alignment This parameter sets whether post print alignment is carried out. The
options are:
Not Performed
Performed
Default - Not Performed
No. Sites This parameter displays the total number of sites.
Minimum - 0
Maximum - 500
Increments - 1
Default - 0
Site Name The unique uppercase name given to a site for identification and which
cannot be mistaken for the name of a created site. The name can have a
maximum of 20 characters.
Site Priority This parameter determines the priority of a site. Where the site is part of a
device, the value applies to the whole device. The options are:
Not Inspected
General
Every Cycle
Default - Every Cycle
Site Alignment This parameter sets what alignment data is reported for each site. The
options are:
X & Y
X Only
Y Only
None
Default - None
Limit Set ID The unique uppercase name given to a set of limits which can be applied to
any site. This enables different sites to be inspected according to different
limits. The name can have a maximum of 20 characters. A maximum of
14 limit sets can be created.
Paste Scaling This parameter enables adjustment of the paste scaling value for the
current site, to cause the value of paste present on the pad, currently
selected in the inspection list, to be reported as 100%. This parameter is
used in conjunction with the Auto Scale function.
Minimum - 0.01
Maximum - 2.00
Increments - 0.01
Default - 1
Site X Coord The coordinate of a site taken from the front left corner of the board, in the
X direction.
Minimum - 0.0mm
Maximum - Board Length
Increments - 0.1mm
Default - 164.1mm
8.42 User Manual Software Version 6
2Di INSPECTION
MENU PARAMETERS

Parameter Definition
Site Y Coord The coordinate of a site taken from the front left corner of the board, in the
Y direction.
Minimum - 0.0mm
Maximum - Board Width
Increments - 0.1mm
Default - 59.5mm
Site Width The width of the site to be inspected.
Minimum - 0.5mm
Maximum - 4.0mm
Increments - 0.01mm
Default - 0.7mm
Site Height The height of the site to be inspected.
Minimum - 0.5mm
Maximum - 4.0mm
Increments - 0.01mm
Default - 4mm
Blockage Warning This parameter sets the amount of aperture blockage required to initiate a
warning.
Minimum - 0%
Maximum - 100%
Increments - 1%
Default - 10%
Blockage Alarm This parameter sets the amount of aperture blockage required to initiate an
alarm.
Minimum - 0%
Maximum - 100%
Increments - 1%
Default - 20%
Smear Warning This parameter sets the amount of screen smear required to initiate a
warning.
Minimum - 0.01 sq. mm
Maximum - 10 sq. mm
Increments - 0.01 sq. mm
Default - 0.1 sq. mm
Smear Alarm This parameter sets the amount of screen smear required to initiate an
alarm.
Minimum - 0.01 sq. mm
Maximum - 10 sq. mm
Increments - 0.01 sq. mm
Default - 0.2 sq. mm
Paste warning This parameter sets the amount of paste on pad required to initiate a
warning.
Minimum - 0%
Maximum - 100%
Increments - 1%
Default - 90%
Paste Alarm This parameter sets the amount of paste on pad required to initiate an
alarm.
Minimum - 0%
Maximum - 100%
Increments - 1%
Default - 80%
Software Version 6 User Manual 8.43
2Di INSPECTION
MENU PARAMETERS

Parameter Definition
Align Warning This parameter sets the amount of X or Y alignment error of the paste to
initiate a warning.
Minimum - 0.005mm
Maximum - 0.25mm
Increments - 0.001mm
Default - 0.025mm
Align Alarm This parameter sets the amount of X or Y alignment error of the paste to
initiate an alarm.
Minimum - 0.005mm
Maximum - 0.25mm
Increments - 0.001mm
Default - 0.03mm
Bridge Warning This parameter sets the distance between adjacent deposits of paste that if
not exceeded initiates a warning.
Minimum - 0.01mm
Maximum - 0.5mm
Increments - 0.005mm
Default - 0.05mm
Bridge Alarm This parameter sets the distance between adjacent deposits of paste that if
not exceeded initiates an alarm.
Minimum - 0.01mm
Maximum - 0.5mm
Increments - 0.005mm
Default - 0.04mm
Volume Warning This parameter sets the volume of paste on pad required to initiate a
warning.
Minimum - 0%
Maximum - 100%
Increments - 1%
Default - 80%
Volume Alarm This parameter sets the volume of paste on pad required to initiate an
alarm.
Minimum - 0%
Maximum - 100%
Increments - 1%
Default - 70%
Screen Graphic This parameter sets the colour of the graphic box drawn around the screen
site. The options are:
Black
White
Default - Black
This parameter has no function on the Horizon and Infinity machines.
Screen Graphic X The position of the inspection window. This parameter is used to finely
adjust the inspection window in the X direction, any adjustment made
affects the site X coord parameter.
Minimum - -3.5mm
Maximum - 3.5mm
Increments - 0.01mm
Default - 0mm
8.44 User Manual Software Version 6
2Di INSPECTION