Dek-265GSX-User-Manual.pdf.pdf - 第304页

IMAGE RECORDING Selecting Save Image saves the inspection object data using the save object command. This option is only available if image recording in set preferences is set to VP or PC disk. If the image recording is …

100%1 / 388
Inspect All Selecting this option clears the alarm panel and changes the beacon back to
green. The inspection sequence is restarted from the beginning. All the existing
alarm information is cleared.
Adjust Inspect Selecting this option displays the following menu:
Edit Global Selecting this option opens the edit global parameters window, allowing
parameters that are used throughout the inspection to be altered.
Edit Limits Selecting this option opens the limit sets window, allowing a set of limit
parameters to be selected and altered.
New Pre-images Selecting this option initiates a pre-print inspection on the next print cycle to
capture the new pre-images. The message ‘New pre-images will be collected
next print cycle’ is displayed.
NOTE
The New Pre-image button is only available if pre-image is set to 1.
Edit Site Selecting this option opens the site parameters window, allowing adjustment of
the site specific parameters.
Inspect Site Selecting this option opens the inspection results window and displays the
following menu:
SelectingNext or Previousmoves the highlight up anddownthelistof site pads.
Selecting Toggle Paste either shows or hides the paste display overlay onto the
monitor. The toggle paste facility on the board image is only functional with the
board inspection type set to advanced. Toggling paste on the screen is only
availableon Horizon and Infinity machinesand only withthe screeninspect type
set to basic or advanced.
Selecting Auto Scale automatically adjusts the paste scaling value for the
current site, to cause the value of paste present, on the pad currently selected in
the inspection result list, to be reported as 100%. This is used where the site pad
causing the alarm is actually a good print.
Reject Selecting this option clears the alarm panel and the board is fed to the output end
of the rail system and held there.
Software Version 6 User Manual 8.39
2Di INSPECTION
OPTIONS AFTER AN INSPECTION ALARM
IMAGE RECORDING
Selecting Save Image saves the inspection object data using the save object
command. This option is only available if image recording in set preferences is
set to VP or PC disk. If the image recording is set to VP disk, the file name is
inspnnn.img, where nnn is the next sequence number to save. If the image
recording is set to PC disk, the file name is inspn.img, where n is a number
cyclingfrom 1 to 5. The first imagesaved afterinitialization isinsp1.img. Files
are overwritten without warning.
NOTE
VP disk saves to the Cognex HD if fitted. It is recommended to use PC disk only
for image recording.
8.40 User Manual Software Version 6
2Di INSPECTION
IMAGE RECORDING
MENU PARAMETERS
Parameter Definition
2D Inspect Rate This parameter sets the number of print cycles between inspection cycles,
with zero indicating no inspection.
Minimum - 0
Maximum - 100
Increments - 1
Default - 0
Stencil Inspect Type This parameter sets the extent of the screen inspection. The options are:
None
Basic
Advanced
Default - Basic
Board Inspect Type This parameter sets the extent of the board inspection. The options are:
None
Basic
Advanced
Default - Basic
Pre-image This parameter sets when a pre-image is taken. The options are:
One - The first board only
Every - Every board
Default - One
Min Sites/Cycle This parameter sets the number of sites to inspect every cycle.
Minimum - Number of Every Cycle sites
Maximum - Total number of sites
Increments - 1
Default - Number of every cycle sites
Warning Limit This parameter determines how many consecutive warnings on the same
site constitute an alarm.
Minimum - 1
Maximum - 20
Increments - 1
Default - 3
Blockage Action This parameter sets the action performed on a blockage alarm. The options
are:
Manual
Automatic
Default - Manual
Blockage Clean This parameter sets the type of screen clean performed on blockage alarm.
The options are:
Mode 1
Mode 2
Default - Mode 1
Smear Action This parameter sets the action performed on a smear alarm. The options
are:
Manual Action
Automatic
Default - Manual
Smear Clean This parameter sets the type of screen clean performed on a smear alarm.
The options are:
Mode 1
Mode 2
Default - Mode 2
Software Version 6 User Manual 8.41
2Di INSPECTION
MENU PARAMETERS