15. Select Set Light (F3). Set Light A histogram is displayed on the monitor and the Fiducial Lighting Parameters window is displayed on the status page. For the silver camera part number 145016, the fiducial lighting pa…

The co-ordinates of the fiducial in the field of view are now displayed on the
screen.
Position the fiducial in the centre of the box graphic.
11.
Use the Next and Previous keys (F4 - F5), to highlight each co-ordinate.
Next Previous
12.
Use the Incr. And Decr. Keys (F6 - F7), to change the parameter value and
move the fiducial in the field of view.
Incr. Decr.
13.
Select Exit (F8).
Exit
14.
Select Fiducial Setup (F3).
Fiducial
Setup
The monitor displays the following:
Software Version 6 User Manual 1.79
MACHINE PROGRAMMING
STAGE 7
BOARDFIDUCIAL1CO-ORDINATES
xxx mm
FIDUCIAL1Y
FIDUCIAL1X
xxx mm
PrinterStatus
ProcessParameters
Background
Dark
AcceptScore
700
Circle Parameters
BoardFiducial1
mm
mm
mm
Diameter
InnerContour
OuterContour
1.80
0.40
0.40
FiducialType
Circle

15.
Select Set Light (F3).
Set
Light
A histogram is displayed on the monitor and the Fiducial Lighting Parameters
window is displayed on the status page.
For the silver camera part number 145016, the fiducial lighting parameters
window is shown below.
For the green camera part number 145550, the fiducial lighting parameters
window is shown below.
16.
Use the Next, Previous, Incr. and Decr. keys (F4 - F7), to highlight and
adjust the lighting parameters to a level whereby the fiducials are just
whiting out, without blooming, default level 8 is usually adequate for the
majority of setups.
Next Previous Incr. Decr.
1.80 User Manual Software Version 6
MACHINE PROGRAMMING
STAGE 7
8
8
8
8
8
8
8
8
8
8
-1.0
-1.5
2.0
2.0
Fiducial Lighting Parameters
mm
mm
mm
mm
Screen Vertical
Screen Inner LR
Screen Inner FR
Screen Outer LR
Screen Outer FR
Board Vertical
Board Inner LR
Board Inner FR
Board Outer LR
Board Outer FR
Window Left
Window Top
Window Width
Window Height
8
8
8
8
-1.0
-1.5
2.0
2.0
Fiducial Lighting Parameters
Screen Vertical
Screen Oblique
Board Vertical
Board Oblique
Window Left
Window Top
Window Width
Window Height

17.
Select Exit (F8).
Exit
18.
Use the Next, Previous, Incr. and Decr. keys (F4 - F7), to highlight and
adjust each of the board fiducial parameters in the left hand box on the
monitor.
Next Previous Incr. Decr.
19.
Select Learn Fiducial (F1).
Learn
Fiducial
Setup the fiducials appearing in the right hand box on the monitor.
20.
Use the Next, Previous, Incr. and Decr. keys (F4 - F7), to highlight and
adjust each circle parameter in turn to obtain the best fit over the fiducial.
Next Previous Incr. Decr.
Software Version 6 User Manual 1.81
MACHINE PROGRAMMING
STAGE 7
PrinterStatus
Boar
d
F
id
uc
i
a
l
1
Background
Dark
AcceptScore
700
FiducialType
Circle
Video Model
To setup a video model, choose Video Model from the Fiducial Type
Parameter.
Circle Parameters
mm
mm
mm
mm
mm
xxx
xxx
xxx
xxx
xxx
Position X
Position Y
Diameter
InnerContour
OuterContour
Video Model
When using video model the parameters are as follows:
Video Model, Position X, Position Y, Fiducial X, Fiducial Y