Dek-265GSX-User-Manual.pdf.pdf - 第189页
Error Message Intrepretation Command Timed Out (Screen Actuators) This error reports that the actuator has failed to move to the demanded position within the time period. Possible causes are: Home sensor fault, if occurr…

Error Message Intrepretation
Command Timed Out
(Belt Motors)
This error reports if a board on the belt fails to move over the
board at left/right sensor within the time period. Possible causes
are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
Mint card faulty.
Problem on the busy line from the mint card.
Command Timed Out
(Camera Axes)
This error reports that the camera has failed to move to the
demanded position within the time period. This error applies to
both the X and Y camera axis. Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
Mint card faulty.
Problem on the busy line from the mint card.
Command Timed Out
(Paste Dispense Carriage)
This error reports that the paste dispense carriage has failed to
move to the demanded position within the time period. Possible
causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
Mint card faulty.
Problem on the busy line from the mint card.
Command Timed out
(Print Carriage)
This error reports that the print carriage has failed to move to the
demanded position within the time period. Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
Mint card faulty.
Problem on the busy line from the mint card.
Command Timed Out
(Print Head)
This error reports that the print head fails to move to the demanded
position within the time period. Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
Mint card faulty.
Problem on the busy line from the mint card.
Command Timed Out
(Proflow)
This error reports that the proflow unit has failed to move to the
demanded position within the time period. Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
Mint card faulty.
Problem on the busy line from the mint card.
Command Timed Out
(Rail System)
This error reports that the moving rail has failed to move to the
demanded position within the time period. Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
Mint card faulty.
Problem on the busy line from the mint card.
4.4 User Manual Software Version 6
ERROR MESSAGES
ERROR MESSAGE LISTING

Error Message Intrepretation
Command Timed Out
(Screen Actuators)
This error reports that the actuator has failed to move to the
demanded position within the time period. Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
Mint card faulty.
Problem on the busy line from the mint card.
Command Timed Out
(Screen Change)
This error reports that the screen change has failed to move to the
demanded position within the time period. Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
Mint card faulty.
Problem on the busy line from the mint card.
Command Timed Out
(Front/Rear Squeegee)
This error reports that the front/rear squeegee has failed to move to
the demanded position within the time period. Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
Mint card faulty.
Problem on the busy line from the mint card.
Downline Board Transfer Fault This error reports that the time the downline interface has waited
for a board has exceeded the time-out.
Downline Machine Not available This error reports that the downline machine is unavailable to
accept the next board.
Dual Shuttle Fault This error reports that the 20 seconds time-out period has been
exceeded when loading or unloading a screen.
Event File Open Error This error reports that there was a problem opening the event log
backup file.
Failed to Determine Tooling
Deviation
This error reports that while monitoring the tooling deviation, the
number of samples (pressure variations) during the print stroke
was less than 2 or the minimum value was zero. This error
message is only valid where tooling deviation is authorized and
enabled.
Check tooling support is sufficient.
Check underside components are clear of tooling.
Front Squeegee Error This error reports that the front squeegee has failed to reach its
fully up position.
Front Squeegee Pressure Error When this error is detected a new window displays the set pressure
reading and the actual pressure reading.
File Error (To be added when details available)
Have All Tooling Pins Been
Removed ?
This message appears for the user to confirm that all magnetic
tooling pins have been removed, before setting up the machine for
a new board file that uses autoflex tooling.
Invalid Calibration Data.
Recalibrate ProFlow Heights
This error reports that the ProFlow calibration data is corrupt or
invalid.
Invalid Calibration Data.
Recalibrate Squeegee Heights
This error reports that the squeegee calibration data is corrupt or
invalid.
Lid Bolt Fault This indicates that the lid bolt has failed to either open or close.
Software Version 6 User Manual 4.5
ERROR MESSAGES
ERROR MESSAGE LISTING

Error Message Intrepretation
No Paste Knead Cycles Selected This error reports when Knead Paste is selected on main menu
page and Knead Deposits in Set Prefs is selected to 0 cycles.
Paste Carriage Error This error reports that the paste carriage has failed to reach its
home position.
Paste Cartridge Tilt Error This error reports that the paste cartridge mechanism has failed to
either make its up or down limit switches.
Pneumatic Power Down This error message reports that the pneumatic supply is either too
low or has been disconnected
Position Error
(Camera)
This error reports that the cameras actual position is not within the
tolerance of 1% of the designated position.
Position Error
(Print Carriage)
This error reports the print carriage actual position is not within
tolerance of its designated position.
Position Error
(Rising Table)
This error reports that the rising table has failed to reach its home
position.
Position Error
(Screen Load)
This error reports that a problem has occurred while unloading the
screen. Possible causes are:
Motor fault Sensor fault
Print Carriage Error This error reports that the print carriage has failed to move.
Proflow Downstop At Limit This error reports when the downstop reaches set limits whilst
using the jog buttons in Diagnostics (Drive Downstop Using Jog
Buttons).
Proflow at movement limit This error reports when the proflow reaches set limits whilst using
jog buttons in Diagnostics(Drive System Using Jog Buttons).
Rail Lifted Error, Check Tooling This error reports that either the left rail lifted sensor or the right
rail lifted sensor are out of their home positions when any of the
following moves are taking place:
Alignment of the screen
Board stop moving into position
Initialization of the machine
Initialization of the autoflex tooling
Possible causes are:
A misfed board
Tooling/object on the rising table striking the underside of the rails
Rear Squeegee Error This error reports that the rear squeegee failed to reach its fully up
position.
Rear Squeegee Pressure Error When this error is detected a new window displays the set pressure
reading and the actual pressure reading.
Rising Table Error This error reports that the rising table has either failed to reach its
fully down position or that when attempting to reach the required
height during the machine cycle did not achieve the positional
accuracy.
Rising Table Out of Position This error reports that either; the camera axes are not at the home
position when the rising table is to be lifted, or the rising table is at
a height greater than vision height by 1mm.
Screen Changer Drive Error
(265GSX only)
This error indicates that no screen movement has been detected
when the screen changer is attempting to move the screen either at
initialization or at a screen change request.
4.6 User Manual Software Version 6
ERROR MESSAGES
ERROR MESSAGE LISTING