Dek-265GSX-User-Manual.pdf.pdf - 第18页

STAGE 1 For machines with the remote board stop option, ensure that the machine is correctly configured for the intended product. Carry out the appropriate one of the following procedures: • Camera to Remote Board Stop -…

100%1 / 388
MACHINE PROGRAMMING
INTRODUCTION This chapter details the procedure for a new product setup, in stages and are as
follows:
Software Version 6 User Manual 1.1
MACHINE PROGRAMMING
INTRODUCTION
STAGE 1
PowerUpandLogOn
STAGE 2B
Loading a Product File -
Using Bar Code
STAGE 2A
Loading a Product File -
Using Function Keys
STAGE 3
Editing a Product File
STAGE 4B
ProFlow Setup
STAGE 4A
Fit Squeegees
STAGE 8
Load Paste
Run a Product in Step Mode
STAGE 9
2Di Setup
STAGE 10
Running a Product
in Run Mode
STAGE 5B
Lt - Loading a Screen
STAGE 5A
GSX - Loading a Screen
STAGE 7
Vision System Setup
STAGE 6B
Tooling Setup -
Vacuum
STAGE 6A
Tooling Setup -
Magnetic Pillars
STAGE 6C
Tooling Setup -
Dedicated Tooling System
STAGE 6D
Tooling Setup -
MultiFlex
STAGE 6E
Tooling Setup -
AutoFlex
STAGE 6F
Tooling Setup -
Fine Pitch AutoFlex
STAGE 1 For machines with the remote board stop option, ensure that the machine is
correctly configured for the intended product. Carry out the appropriate one of
the following procedures:
Camera to Remote Board Stop - LHS Configuration
Camera to Remote Board Stop - RHS Configuration
Remote Board Stop - LHS to RHS Configuration
Remote Board Stop - RHS to LHS Configuration
Remote Board Stop - Same Side Configuration
Remote Board Stop to Camera Board Stop
See Technical Reference Manual, Rising Table Module Chapter, Replacement
Procedures, for the first five procedures and Technical Reference Manual,
Camera and Vision System Module Chapter, Replacement Procedures for the
Remote Board Stop to Camera Board Stop procedure.
Power Up and
Log On
1.
Turn the main isolator switch to On.
2.
When the message ‘Press SYSTEM Switch To Initialize Printer or Select
Diagnostics or Load Data’ is displayed in the message prompt bar, either:
a) Select Load Data (F2) if the loaded product is unknown or needs to be
changed.
b) Go to Step 5 if the loaded product file is known to be the correct one.
Load
Data
The Load Data File window is displayed:
1.2 User Manual Software Version 6
MACHINE PROGRAMMING
STAGE 1
265 Test 1
Load Data File
10x10
265 Test 1
Apple
Calibra
Default
Dek 04
Dek 03
Test 1
Xray
Search
265 Test 1
Product ID
3.
Use the Left, Right, Up or Down function keys (F4 - F7) to highlight the
required file.
Left Right Up Down
4.
Press Load (F1).
Load
5.
Initialize the machine by pressing the System button.
The selected file is now displayed on the status page.
The operator can change the language used in the display menus.
To select a different language continue with Step 6. If the correct language is
loaded go to Step 12.
6.
From the status page displayed, select Setup (F6).
Setup
7.
Select Change Language (F7).
Change
Language
8.
A list of installed languages is displayed. Select Up (F5), orDown(F6) until
the desired language is highlighted.
Software Version 6 User Manual 1.3
MACHINE PROGRAMMING
STAGE 1