31. Select Board Clamps (F3), to open the clamps. Board Clamps 32. Remove the board from the rails. 33. Select Head (F2). Head 34. Remove the head prop. Lower the printhead using two button control. 35. Press the System …

100%1 / 388
26. Remove the head prop. Lower the printhead using two button control.
27.
Press the System button.
28.
Select Home Position (F7).
Home
Position
29.
Select Raise Head (F2).
Raise
Head
30. Raise the printhead using two button control. Fit the head prop.
1.42 User Manual Software Version 6
MACHINE PROGRAMMING
STAGE 6C
31.
Select Board Clamps (F3), to open the clamps.
Board
Clamps
32. Remove the board from the rails.
33.
Select Head (F2).
Head
34. Remove the head prop. Lower the printhead using two button control.
35.
Press the System button.
36.
Select Exit (F8).
Exit
37. Go to Stage 7.
Software Version 6 User Manual 1.43
MACHINE PROGRAMMING
STAGE 6C
STAGE 6D
Tooling Setup - MultiFlex
CAUTION
BOARD CLAMPS. Care must be taken to ensure that the board clamps
are not damaged when removing or replacing tooling.
NOTE
Setting up the MultiFlex tooling is to be performed off the machine.
1. Create a box the same size as the board using the side plates.
2. Use the board width and board length dimensions to position the box
correctly.
3. Place the PCBon a flat surface,with the components thatare under the board
during printing uppermost.
4. Position the acetate template, supplied with the tooling, over the PCB such
that the front edge of the board is aligned with the arrow indicators on the
template. Ensure also that the centreline of the board is aligned with the
template zero.
1.44 User Manual Software Version 6
MACHINE PROGRAMMING
STAGE 6D
WARNING
BOARD CLAMPS. EXTREME CARE MUST BE EXERCISED WHEN
WORKING IN THE TOOLING AREA OF THE MACHINE TO AVOID
INJURY. THE FOILS ON THE FRONTAND REAR BOARD CLAMPS
AREVERYSHARP.