Dek-265GSX-User-Manual.pdf.pdf - 第46页
STAGE 6B Tooling Setup - Vacuum CAUTION BOARD CLAMPS. Care must be taken to ensure that the board clamps are not damaged when removing or replacing tooling. 1. Select Change Tooling (F6). Change Tooling 2. Select Full Wi…

31.
Press the System button.
32.
Select Exit (F8).
Exit
33. Go to Stage 7.
Software Version 6 User Manual 1.29
MACHINE PROGRAMMING
STAGE 6A

STAGE 6B
Tooling Setup - Vacuum
CAUTION
BOARD CLAMPS. Care must be taken to ensure that the board clamps
are not damaged when removing or replacing tooling.
1.
Select Change Tooling (F6).
Change
Tooling
2.
Select Full Width (F5).
Full
Width
3.
Select Raise Head (F2).
Raise
Head
4. Raise the printhead using two button control. Fit the head prop.
1.30 User Manual Software Version 6
MACHINE PROGRAMMING
STAGE 6B
WARNING
BOARD CLAMPS. EXTREME CARE MUST BE EXERCISED WHEN
WORKING IN THE TOOLING AREA OF THE MACHINE TO AVOID
INJURY. THE FOILS ON THE FRONTAND REAR BOARD CLAMPS
AREVERYSHARP.

5. The vacuum box can now be fitted into the appropriate location holes in the
tooling plate. Ensure that the vacuum box is placed into the correct set of
holes, taking regard of the type of screen being used and hence the position
of the fixed rail.
6.
Select Head (F2).
Head
7. Remove the head prop. Lower the printhead using two button control.
8.
Press the System button.
Software Version 6 User Manual 1.31
MACHINE PROGRAMMING
STAGE 6B