00196608-01_AI_Stationaere_Kamera_Typ33_36_de_en.pdf - 第100页
Brief Description Product Description Technical Data. 100 Stationary Camera Type 33/36 Stationäre Kamera Typ 33/ 36 2.1.1 Technical Data. 2.1.1.1 Component Camera, Stationary, P&P (Type 33) 55x45 The "component …

Brief Description
Product Description
Stationary Camera Type 33/36 Stationäre Kamera Typ 33/36 99
2 Brief Description
2.1 Product Description
Installation position
Camera structure
1. Stationary camera, type 33/36 (IC camera)
2. Stationary camera, type 25 (FC camera)
Component camera, stationary P&P (type 33) 55x45
Component camera, stationary P&P (type 36) 32x32 dig-
ital
1. Upper section of camera (illumination unit)
2. Lower section of camera
3. Glass sheet
4. Camera electronics
5. Holes for fastening screws
NOTICE
The upper section of the camera is assigned specifically to the lower section of the camera!
The upper section of the camera may not be used with a different bottom section. Both the up-
per and lower sections are mechanically and electrically coordinated and may not be ex-
changed for use with other cameras. The serial and version numbers of the top and bottom
sections of the camera must be identical.

Brief Description
Product Description Technical Data.
100 Stationary Camera Type 33/36 Stationäre Kamera Typ 33/36
2.1.1 Technical Data.
2.1.1.1 Component Camera, Stationary, P&P (Type 33) 55x45
The "component camera stationary P&P (type 33) 55x45" provides a resolution of 41 µm and a wider
available component spectrum of up to 55x45 mm. This stationary camera can, for example, be ordered
if you require greater resolution or when you need to place multiple components which are larger than
the field of view supported by your standard camera. For more information about this data, refer to the
specification documents for the relevant placement head or for the standard camera.
2.1.1.2 Component Camera, Stationary, P&P (Type 36) 32x32
The placement accuracy of the "component camera stationary P&P (type 36) 32x32" is specific to the
machine and head used. For more information about this data, refer to the specification documents for
the relevant placement head or for the standard camera.
2.1.2 Version Overview
Component dimensions 0.5 mm x 0.5 mm up to 55 mm x 45 mm
Component spectrum 0402, MELF, SO, PLCC, QFP, electrolytic capaci-
tors, BGA
Min. lead pitch 0.30 mm
Min. lead width 0.15 mm
Min. ball pitch 0.35 mm
Min. ball diameter 0.20 mm
Field of view
65x50 mm
2
Method of illumination Front-lighting (6 levels, programmable as re-
quired)
Component dimensions 0.8 x 0.8 mm イ to 32 x 32 mm イ (simple measure-
ment)
Component spectrum 0603, MELF, SO, PLCC, QFP, electrolytic capaci-
tors, BGA
Min. lead pitch 0.40 mm
Min. lead width 0.24 mm
Min. ball pitch 0.56 mm
Min. ball diameter 0.32 mm
Field of view
38x38 mm
2
Method of illumination Front-lighting (6 levels, programmable as re-
quired)
Version
SST33
Version
SST36
Description
01, 02 --- Without CAN controller, VCU required (CAN and power supply via VCU)
03 to 06 01 With CAN controller (as TQ module), VCU not required, 8 pin DIP switch on the
driver board
From 06 From 04 Simpler assembly with key holes
From 07 From 05 With CAN controller (integrated on the board), VCU not required, 6 pin DIP switch
on the driver board

Brief Description
Version Overview Prerequisites and Restrictions
Stationary Camera Type 33/36 Stationäre Kamera Typ 33/36 101
2.2 Prerequisites and Restrictions
▪ Type 33 stationary cameras can be used in the SX series, X series, D3 and D1 machines.
▪ Type 36 stationary cameras can only be used in D1 machines.
▪ The camera design and the assembly procedure for each camera is generally the same for the indi-
vidual machines. Any differences will be explicitly indicated in this guide.
▪ When using a C&P20 head, make sure that there are no stationary cameras fitted in the same place-
ment area.
▪ When using X series or SX series machines, you may need to move the COT insert, depending on
your machine configuration.
▪ A type 33 stationary camera of version 1 or 2 can only be used in X series machines up to number
326.
From version 3, it can also be used with SIPLACE D series, SX and X series machines of number
326 or higher.
▪ When fitting the camera in an X series or SX4 machine, you will need to have two hotlink cards in
the box PC.
WARNING
Head crash risk by changeover to C&P20 head
When changing the placement head from a TwinHead or CPP to a C&P20, you will need to dis-
mantle all stationary component cameras (stationary P&P, type 33, 55x45, and type 25, 16x16)
from the TwinHead.
If this is not done, there is a risk that the C&P20 head could crash with the camera housing.
WARNING
Head crash by changeover to CPP head
When changing the placement head from a TwinHead to a CPP, you will need to install the sta-
tionary component camera (type 33, 55x45, digital) in the lower position.