00196608-01_AI_Stationaere_Kamera_Typ33_36_de_en.pdf - 第129页

Installation Mechanical Assembly Assembly in a D1 Machine Stationary Camera Typ e 33/36 Stationäre Kamera Typ 33/36 129 Fitting a new camera Stationary ca mera - set screws (D1) ► Use the two set screws (1) a s an assemb…

100%1 / 172
Installation
Assembly in a D1 Machine Mechanical Assembly
128 Stationary Camera Type 33/36 Stationäre Kamera Typ 33/36
3.3.2 Mechanical Assembly
Equipment required:
2x set screw (DIN913-M6x50-ST) [03005958-xx]
Dismantling the existing camera
Pull the illumination unit up and off the camera.
Remove the bottom cover.
Disconnect the camera from all electrical connections.
Replace the top two fastening screws for the camera with set screws (DIN913-M6x50-ST
[03005958-xx]).
Unscrew and remove the bottom two fastening screws on the camera.
Take the camera base unit off the set screws. Take care that the fiducial sandwich plate does not
slip off the set screws.
CAUTION
Observe the installation height
When fitting the camera, observe the correct installation height. Otherwise there is a risk of
head crash!
Please also observe section "4.1 Installation Height of the Stationary Camera" [ 153].
NOTICE
Same parts: camera type 33 and type 36
For the D1 you can use the same screws and "sandwich plate for fiducial IC camera"
[03039370-xx] for both type 33 and type 36 stationary cameras.
The "component reject assembly for P&P head" [03047406-xx] remains in the machine.
DANGER
Fiducial sandwich plate
The fiducial sandwich plate is very heavy and, when fitted, only clamped between the camera
and machine base.
Before removal, make sure that the sandwich plate does not fall down.
Installation
Mechanical Assembly Assembly in a D1 Machine
Stationary Camera Type 33/36 Stationäre Kamera Typ 33/36 129
Fitting a new camera
Stationary camera - set screws (D1)
Use the two set screws (1) as an assembly aid for the
camera fiducial plate and the camera base unit. The
Allen key side of the set screws must point to the out-
side, so that they can be unscrewed again.
Fiducial sandwich plate [03039370-xx]
Suitable for IC camera type 36 and type 33
Use in SIPLACE D1 machines
CAUTION!
CAUTION! For assembly in D1 machines, al-
ways use the fiducial sandwich plate [03039370-xx]. If
you do not, machine accuracy will not be guaranteed and
there will be a risk of a head crash occurring.
Stationary camera – sandwich plate (D1)
Fit the fiducial sandwich plate onto the set screws.
These must exactly match the holes in the machine
frame and be fastened with the recess at the top left.
Installation
Assembly in a D1 Machine Mechanical Assembly
130 Stationary Camera Type 33/36 Stationäre Kamera Typ 33/36
Fit the camera base unit onto the set screws and fasten this base unit, together with the fiducial sand-
wich plate, using two socket head screws (Allen screws) DIN912-M6x35-8.8 [00845062-xx].
Replace the two set screws with two socket head screws (Allen screws) DIN912-M6x35-8.8
[00845062-xx]. Screw the camera tight.
Stationary camera - camera base plate (D1)
1. Stationary camera
2. Screws DIN912-M6x35-8.8 [00845062-xx]
3. DIP switch
4. Power supply
5. CAN bus
6. Camera bus
7. Opening for camera cable in machine frame
CAUTION
Do not hold or carry the camera by its electronics unit.
The camera electronics assembly is a sensitive unit and can be easily damaged.
CAUTION
Remove the set screws!
Make sure that no set screws are left behind the camera. If these are left, the camera might be
fitted at a slant.
If you are unable to remove the set screws, dismantle the camera again and move the set