00196608-01_AI_Stationaere_Kamera_Typ33_36_de_en.pdf - 第110页

Installation Installation on X Series and D3 Machines Installation Position X Series and D3 110 Stationary Camera Type 33/36 Stationäre Kamera Typ 33/ 36 3.2 Installation on X Se ries and D3 Machines Required installatio…

100%1 / 172
Installation
Moving COT Insert with X Tables General Preparations
Stationary Camera Type 33/36 Stationäre Kamera Typ 33/36 109
3.1.1.4 Moving the COT Insert
On both sides of the COT insert you will find a black
cap (1). Remove the cap to the inside of the machine,
if you need to access the fitting screw behind it. To do
this, simply loosen the screw fastening the cap and
take off the cap.
NOTICE!
The cap on the outer side need not be removed.
Mark the mounting position of the COT insert.
Loosen the five screws (1) fastening the COT insert.
Loosen the fitting screw (2) on the inside of the ma-
chine.
CAUTION!
The cover of the power supply (2) must be closed.
If the cover of the power supply is not closed there is a
risk that the COT insert will fall out when moved..
Close the cover of the power supply.
Pull out the COT insert carefully until it touches the
protective door of the power supply (1).
1
1
1
1
2
1
Installation
Installation on X Series and D3 Machines Installation Position X Series and D3
110 Stationary Camera Type 33/36 Stationäre Kamera Typ 33/36
3.2 Installation on X Series and D3 Machines
Required installation kits:
See"2.3 Scope of Delivery" [ ➙ 102]
Installation kit: stationary camera type 33 for CPP head fitted in X series [00119782-xx]
The stationary camera (type 33) is already included in the HRK for TwinHead used in X series machines.
3.2.1 Installation Position X Series and D3
Installation position of cameras (using example of X3)
1 IC camera, type 33 3 Component reject bin
2 FC camera or 3D coplan Loc 1-
4
Location 1 - 4
NOTICE
TwinHead
The FC camera and the 3D coplan module are only possible together with a TwinHead. Only
one of these options can be fitted at this installation position, meaning that either the FC camera
or the 3D coplan module can be used.
Installation
Mechanical Assembly Installation on X Series and D3 Machines
Stationary Camera Type 33/36 Stationäre Kamera Typ 33/36 111
3.2.2 Mechanical Assembly
NOTICE
Configuration X2, X4 and D3
In the SIPLACE X2 the cameras can be configured in PA1 in the same way as they are in
PA2 of SIPLACE X3 machines. In this case, location 1 equates to location 3.
In the SIPLACE X4 the cameras can be configured in PA2 in the same way as they are in
PA1 of SIPLACE X3 machines. In this case, location 1 equates to location 3.
The SIPLACE D3 can be configured in exactly the same way as the SIPLACE X3.
CAUTION
Observe the installation height
When fitting the camera, observe the correct installation height. Otherwise there will be a risk
of head crash!
Please also observe section "4.1 Installation Height of the Stationary Camera" [ 153].
1. Upper position
2. Lower position
3. Position of grub screws for cameras up to FS05
4. Cable duct in machine base with camera cables
Fiducial sandwich plate [03022077-xx]
Suitable for IC camera type 33 and type 22
Use in SIPLACE X series, HF and D3 machines
CAUTION!
For assembly in X series and D3 machines, always use
the fiducial sandwich plate [03022077-xx]. If you do not,
machine accuracy will not be guaranteed and there is a